Skip to main content
. 2018 Feb 1;10(2):169. doi: 10.3390/nu10020169

Table 1.

Baseline laboratory measurements in the 2015 ISA-Capital. São Paulo, 2015.

Analyte Sample Technical Reference
Vitamin A (retinol) Heparinized plasma High performance liquid chromatography method (Ref. # KC 1600; Immundiagnostik AG, Bensheim, HE, Germany)
Vitamin C (ascorbic acid) Heparinized plasma High performance liquid chromatography method (Ref. # KC 2900; Immundiagnostik AG, Bensheim, HE, Germany)
Vitamin E (alpha-tocopherol) Heparinized plasma High performance liquid chromatography method (Ref. # KC 1600; Immundiagnostik AG, Bensheim, HE, Germany)
Vitamin D (cholecalciferol-25 (OH)D3) Serum Chemiluminescence (Diasorin kit, Stillwater, MN, USA)
Vitamin B6 (pyridoxal-5-phosphate) Heparinized plasma High performance liquid chromatography method (Ref. # KC 2100; Immundiagnostik AG, Bensheim, HE, Germany)
Vitamin B9 (folate) Serum and erythrocytes Chemiluminescent immunoassay (Ref. # A98032; Beckman Coulter Inc.; Fullerton, CA, USA)
Vitamin B12 (cobalamin) Serum Chemiluminescent immunoassay (Ref. # 3300; Beckman Coulter Inc.; Fullerton, CA, USA)
Parathormone Serum Elecsys 2010 kit, Roche Diagnostics, Indianapolis, ID, USA
Iron Serum Colorimetric assay (Cobas; Roche Diagnostics GmbH, Mannheim, BW, Germany)
Ferritin Serum Chemiluminescent immunoassay (Ref. # 33020; Beckman Coulter Inc.; Fullerton, CA, USA)
Transferrin Serum Kinetic nephelometry (Ref. # OSR6152; Beckman Coulter Inc.; Fullerton, CA, USA)
Whole blood cell count Whole blood Automatic method
Magnesium Serum Photometric color assay (Ref. # OSR6189; Beckman Coulter Inc.; Fullerton, CA, USA)
Zinc Serum Flame atomic absorption method (AAnalyst 100 instrument; Perkin Elmer, Norwalk, CT, USA) [10]
Total cholesterol Serum Trinder reaction (cholesterol oxidase) (Cobas; Roche Diagnostics GmbH, Mannheim, BW, Germany)
Low-density lipoprotein-cholesterol Serum Homogeneous enzymatic colorimetric assay (Cobas; Roche Diagnostics GmbH, Mannheim, BW, Germany)
High-density lipoprotein-cholesterol Serum Homogeneous enzymatic colorimetric assay (Cobas; Roche Diagnostics GmbH, Mannheim, BW, Germany)
Triacylglycerol Serum Enzymatic colorimetric assay (glycerol phosphate peroxidase) (Cobas; Roche Diagnostics GmbH, Mannheim, BW, Germany)
Very low-density lipoprotein-cholesterol Serum Values were calculated by dividing the triglyceride values by five
Non-high-density lipoprotein-cholesterol Serum Values were determined as the difference between the values of total cholesterol and high-density lipoprotein-cholesterol
Glucose Sodium fluoride plasma Colorimetric enzymatic assay of glucose oxidase (Trinder reaction) (Cobas; Roche Diagnostics GmbH, Mannheim, BW, Germany)
Insulin Ethylenediamine tetraacetic plasma Multiplex immunoassay (LINCOplex®; Linco Research Inc., St. Charles, MO, USA)