Skip to main content
. 2018 Feb 15;167:191–202. doi: 10.1016/j.neuroimage.2017.11.031

Fig. 8.

Fig. 8

In-plane spatial distribution of breathing-induced field fluctuations in sagittal and transversal slices acquired during normal free breathing. A) Mean magnitude image of FLASH acquisition. B) Standard deviation of measured field fluctuations. D) Standard deviation of field residual after removing the field accounted for by the respiratory trace model (Simulated trace corr.). C,E) Standard deviation after subtracting the contribution of up to 1st- or 3rd-order spherical harmonic fields in-plane (Simulated shimming). F) Standard deviation of field residual after subtracting the contribution of the first in-plane PC (Simulated PC corr.). G-H) First and second in-plane principal component.