Skip to main content
. 2018 Feb 1;18(2):426. doi: 10.3390/s18020426

Figure 6.

Figure 6

Figure 6

(a,b) Measured impedance spectrum (10 Hz–100 kHz) of nf-EIS and (c,d) f-EIS. (e) Percentage change of impedance magnitude at 100 Hz and equivalent circuit factors of the two EIS-sensors (The equivalent circuit fitting residual, r2 = 0.9802 for nf-EIS and r2 = 0.9137 for f-EIS).