Total charge and duration of the duty-cycle events shown in Figure 9.

Drip RTC SD Save
Before Optimization:
Duration (ms) 87 140 1200
Charge required (mAs) 0.2324 0.4056 5.980
After Optimization:
Duration (ms) 89 157 433
Charge required (mAs) 0.0050 0.0403 2.496