Skip to main content
. Author manuscript; available in PMC: 2019 Apr 1.
Published in final edited form as: Surgery. 2017 Dec 11;163(4):866–869. doi: 10.1016/j.surg.2017.10.038

Table 1.

Morphometric comparison between surgically detected stenotic and non-stenotic arteriovenous fistula segments

Stenotic Non-Stenotic P-value
Intimal Area (mm2) 3.33 (2.29–5.16) 3.33 (1.94–4.86) 0.26
Max. Intima Thickness (mm) 0.98 (0.78–1.20) 0.75 (0.54–1.08) 0.22
Min. Intima Thickness (mm) 0.11 (0.05–0.43) 0.09 (0.05–0.31) 0.18
Max. Intima-Media Thickness (mm) 1.38 (1.30–1.57) 1.14 (0.84–1.38) 0.13
Min. Intima-Media Thickness (mm) 0.30 (0.23–0.88) 0.37 (0.17–0.70) 0.22
Intima/Media Area Ratio 1.00 (0.70–1.20) 0.97 (0.63–1.18) 0.73

Values are reported as median (interquartile range).