Table 3.

Sentinel lymph node detection rates based on dye technique used.

Technique Any SLN Bilateral Unilateral Para-aortic only None
Indocyanine green (n=62) 57 (92%) 32 (52%) 23 (37%) 2 (3%) 5 (8%)
Blue dye only (n=28) 23 (82%) 11 (39%) 12 (43%) 0 5 (18%)
Blue dye + technetium-99 (n=11) 10 (91%) 9 (82%) 1 (9%) 0 1 (9%)
Total (n=101) 90 (89%) 52 (58%) 36 (40%) 2 (2%) 11 (11%)

P = 0.35