Skip to main content
. 2018 Mar 18;11(3):354–362. doi: 10.18240/ijo.2018.03.02

Table 2. Comparison of refractive state between the control eyes and the LI eyes during defocus.

Time Control eye (n=5)
LI eye (n=5)
Z P (M-W test)
Median Min, max P (S-W test) Median Min, max P (S-W test)
Before 4.25 4.0, 4.25 0.006 4.00 4.0, 4.25 0.000 -1.225 0.221
One week 3.50 3.0, 4.0 0.377 3.25 2.75, 3.75 0.967 -1.057 0.290
Two weeks 3.75 3.0, 4.0 0.054 3.00 2.75, 3.50 0.421 -2.115 0.034a

LI: Lens-induced. Shapiro-Wilk test (S-W test) was used to test normality. Mann-Whitney test (M-W test) was used to compare the difference between the two groups. Data were expressed as median (min, max). aP<0.05 for significant difference between the control eye and the LI eye.