Skip to main content
. 2018 Mar 18;11(3):462–469. doi: 10.18240/ijo.2018.03.17

Table 3. Preoperative and postoperative visual acuity and refractive errors.

Parameters Eye Preoperative Postoperative P
UDVA (logMAR) Dominant eye 0.61±0.50 0.05±0.14 0.000
Non-dominant eye 0.70±0.50 0.32±0.26 0.001
Binocular 0.47±0.42 0.01±0.05 0.000
UNVA (logMAR) Dominant eye 0.65±0.48 0.52±0.22 0.418
Non-dominant eye 0.51±0.43 0.05±0.07 0.003
Binocular 0.42±0.42 0.04 ±0.07 0.008
UIVA (logMAR) Dominant eye 0.68±0.55 0.39±0.22 0.090
Non-dominant eye 0.63±0.43 0.40±0.17 0.070
Binocular 0.53±0.45 0.25±0.16 0.049
MRSE (D) Dominant eye -2.37±2.96 -0.22±0.73 0.001
Non-dominant eye -2.42±2.89 -1.36±0.83 0.068
Spherical (D) Dominant eye -2.12±3.01 -0.14±0.69 0.002
Non-dominant eye -2.16±2.87 -1.22±0.84 0.106
Cylindrical (D) Dominant eye -0.51±0.50 -0.14±0.19 0.001
Non-dominant eye -0.53±0.38 -0.27±0.28 0.006

UDVA: Uncorrected distant visual acuity; UNVA: Uncorrected near visual acuity; UIVA: Uncorrected intermediate visual acuity; logMAR: Logarithm of the minimum angle of resolution; MRSE: Manifest refraction spherical equivalent; Spherical: Spherical refractive error; Cylindrical: Cylindrical refractive error; D: Diopters. Paired t-test was used for statistical analysis. P values <0.05 were considered statistically significant.

mean±SD