Table 1. Complications of CT-guided hook wire localization.
Author | Number | Pneumothorax (%)/drainage (%) | Intrapulmonary hemorrhage (%) | Wire dislodgement (%) | SAE (%) |
---|---|---|---|---|---|
Thaete et al. (2)* | 100 | 48 (48.0)/0 | Not mentioned | 22 (22) | 0 |
Dendo et al. (3) | 168 | 54 (32.1)/2 (1.2) | 25 (14.9) | 4 (2.4) | 0 |
Ciriaco et al. (4) | 53 | 4 (7.5)/0 | Not mentioned | 4 (7.5) | 0 |
Yoshida et al. (5) | 57 | 28 (49.1)/0 | 17 (29.8) | 1 (1.8) | 0 |
Seo et al. (6) | 174 | 69 (39.7)/0 | 62 (35.6) | 8 (4.6) | 0 |
Ichinose et al. (7) | 417 | 284 (68.1)/19 (4.6) | 37 (8.9) | 2 (0.5) | 1 (0.2) |
Suzuki et al. (8) | 161 | 61 (37.9)/0 | 58 (34.8) | 4 (2.5) | 1 (0.6) |
Iguchi et al. (9) | 267 | 150 (56.2)/3 (1.1) | 69 (25.8) | 1 (0.4) | 1 (0.4) |
*, Thaete et al. used both hook wire placement and methylene blue injection simultaneously. SAE, systemic air embolism.