Table 2. Errors discovered AFTER (n=466) blood transfusion by type of hospitals, TESS1 2008 – 2011.

Type of Transfusion error Small
(less than 2,000 transfusions per year)
Medium
(2,000 to 10,000 transfusions per year)
Large
(more than 10,000 transfusions per year)
Overall
Freq. Rate Freq. Rate Freq. Rate Freq. Rate
Distributor codes 0 - 2 1:117,432 0 - 2 1:439,663
Product check-in 0 - 0 - 3 1:206,374 3 1:293,109
Unit storage 0 - 0 - 1 1:619,123 1 1:879,326
Inventory management 2 1:12,670 3 1:78,288 2 1:309,562 7 1:125,618
Product request 3 1:6,642 5 1:47,934 56 1:11,103 64 1:13,771
Request for pick-up 0 - 0 - 1 1:621,772 1 1:881,366
Product selection 0 - 3 1:94,614 10 1:65,484 13 1:73,786
Unit manipulation 0 - 4 1:70,961 2 1:327,418 6 1:159,870
Unit issue 2 1:9,264 11 1:21,308 30 1:20,224 43 1:19,991
Unit transfusion 4 1:4,632 192 1:1,221 82 1:7,399 278 1:3,092
Sample handling 0 - 0 - 7 1:52,289 7 1:89,415
Sample receipt 0 - 4 1:51,917 18 1:20,335 22 1:28,450
Sample testing 0 - 3 1:112,172 14 1:58,353 17 1:70,731
Miscellaneous 0 - 0 N/A 2 N/A 2 N/A
Total 11 N/A 227 N/A 228 N/A 466 N/A

1TESS= Transfusion Error Surveillance System