Table 4. Dosimetric comparison for organs at risk (OARs) in two groups (mean ± SD).

Organs at risk HT-SBRT X-SBRT P value
Total lung (%)
   V5 26.10±12.30 15.00±5.86 0.001
   V10 14.49±7.34 9.83±4.49 0.009
   V20 6.38±3.36 4.45±2.25 0.001
   V30 3.24±1.82 2.66±1.28 0.075
Mean lung dose (Gy) 4.99±2.24 3.81±1.76 0.005
Max spinal cord (Gy) 9.17±4.58 3.42±1.87 0.010
Mean heart dose (Gy) 4.52±4.46 2.90±2.28 0.584

SD, standard deviation; HT-SBRT, helical tomotherapy stereotactic body radiation therapy; X-SBRT, X-knife stereotactic body radiation therapy.