Skip to main content
. 2018 Feb 27;11(3):346. doi: 10.3390/ma11030346

Table 1.

Test Parameters.

Specimen No. of Tests Test Type 1 Description
T-A 3 TS Test at ambient temperature. No heat exposure.
T-100 3 TS Test at ambient temperature after exposure to temperature of 100 °C at constant load.
T-200 3 TS Test at ambient temperature after exposure to temperature of 200 °C at constant load.
T-400 3 TS Test at ambient temperature after exposure to temperature of 400 °C at constant load.
B-A 3 PO Test at ambient temperature. No heat exposure.
B-100 3 PO Test at ambient temperature after exposure to temperature of 100 °C.
B-200 3 PO Test at ambient temperature after exposure to temperature of 200 °C.
B-400 3 PO Test at ambient temperature after exposure to temperature of 400 °C.

1 TS: Tensile strength of GFRP bar; PO: Pull-out bond test