Table 1.
Specimen | No. of Tests | Test Type 1 | Description |
---|---|---|---|
T-A | 3 | TS | Test at ambient temperature. No heat exposure. |
T-100 | 3 | TS | Test at ambient temperature after exposure to temperature of 100 °C at constant load. |
T-200 | 3 | TS | Test at ambient temperature after exposure to temperature of 200 °C at constant load. |
T-400 | 3 | TS | Test at ambient temperature after exposure to temperature of 400 °C at constant load. |
B-A | 3 | PO | Test at ambient temperature. No heat exposure. |
B-100 | 3 | PO | Test at ambient temperature after exposure to temperature of 100 °C. |
B-200 | 3 | PO | Test at ambient temperature after exposure to temperature of 200 °C. |
B-400 | 3 | PO | Test at ambient temperature after exposure to temperature of 400 °C. |
1 TS: Tensile strength of GFRP bar; PO: Pull-out bond test