Skip to main content
. 2018 Mar 21;33(1):114–120. doi: 10.3803/EnM.2018.33.1.114

Table 4. Previously Reported Complications for Ultrasound-Guided Core Needle Biopsy.

Study No. of nodule Hematoma Edema Hemoptysis Infection Hoarseness Vasovagal reaction Dysphagia Total
Quinn et al. (1994) [21] 102 1 1
Liu et al. (1995) [22] 100 0
Taki et al. (1997) [23] 74 0
Pisani et al. (2001) [24] 32 0
Screaton et al. (2003) [25] 209 3 1 4
Harvey et al. (2005) [26] 79 0
Renshaw et al. (2007) [27] 377 1 1
Strauss et al. (2008) [28] 81 0
Zhang et al. (2008) [29] 225 0
Khoo et al. (2008) [30] 359 8 2 2 1 13
Park et al. (2011) [8] 54 1 1
Samir et al. (2012) [31] 90 0
Sung et al. (2012) [32] 555 11 9 20
Na et al. (2012) [7] 225 5 3 8
Yunker et al. (2013) [33] 74 0
Yeon et al. (2013) [9] 155 1 2 3
Hahn et al. (2013) [34] 88 0
Nasrollah et al. (2013) [35] 40 0
Ha et al. (2013) [36] 85 0
Hakala et al. (2013) [37] 52 0
Lee et al. (2014) [38] 125 0
Choi et al. (2014) [39] 191 1 1
Nasrollah et al. (2014) [16] 61 1 1
Trimboli et al. (2014) [40] 31 0
Zhang et al. (2014) [41] 369 2 2 4
Min et al. (2014) [12] 104 0
Ha et al. (2014) [11] 264 2 1 3
Total 4,201 35 15 1 3 3 2 1 60