Table 1.
Tank Number | Rainwater Use | Filter on Tank | Positive to Total Coliforms/8 Samples | Positive to E. coli/8 Samples | Total Coliforms: Minimum and Maximum Detection | E. coli: Minimum and Maximum Detection | Roof Material | Tank Material | TV Antenna on Rooftop | Hanging Canopy |
---|---|---|---|---|---|---|---|---|---|---|
1 | Drinking | No | 8 | 6 | 18.5–2419.6 | 1.0–59.1 | Galvanized | Galvanized | Yes | No |
2 | Drinking | Yes (before filter) | 8 | 6 | 1046.2–613.1 | 866.4–461.1 | Galvanized | Polyethylene | Yes | No |
Yes (after filter) | 8 | 5 | 28.8–365.4 | 1.0–13.4 | ||||||
3 | Drinking | Yes (before filter) | 7 | 4 | 58.6–≥2419.6 | 11.0–365.4 | Galvanized | Polyethylene | Yes | No |
Yes (after filter) | 5 | 2 | 42.6–866.4 | 1.0–5.2 | ||||||
4 | Drinking | No | 8 | 5 | 1.0–≥2419.6 * | 1.0–980.4 | Galvanized | Polyethylene | Yes | No |
5 | Drinking | Yes (before filter) | 8 | 7 | 140.8–≥2419.6 * | 13.2–1986.3 | Tiles | Polyethylene | No | Yes |
Yes (after filter) | 7 | 5 | 172.3–648.8 | 2.0–50.4 | ||||||
6 | Drinking | No | 8 | 6 | 5.2–≥2419.6 * | 1.0–7.2 | Tiles | Polyethylene | Yes | Yes |
7 | Drinking | Yes (before filter) | 8 | 5 | 1.0–≥2419.6 * | 1.0–≥2419.6 * | Galvanized | Galvanized | No | Yes |
Yes (after filter) | 6 | 3 | 1.0–≥2419.6 * | 1.0–≥2419.6 * | ||||||
8 | Drinking | No | 6 | 3 | 2.0–≥2419.6 * | 1.0–39.3 | Galvanized | Concrete | No | No |
9 | Drinking | Yes (before filter) | 8 | 3 | 256.5–≥2419.6 * | 2.0–22.8 | Galvanized | Polyethylene | Yes | No |
Yes (after filter) | 2 | 1 | 24.3–1553.1 | <1.0–1.0 | ||||||
10 | Drinking | Yes (before filter) | 6 | 3 | 32.7–1986.3 | 13.4–648.8 | Galvanized | Polyethylene | Yes | Yes |
Yes (after filter) | 3 | 2 | 3.0–88.2 | 1.0–11.0 | ||||||
11 | Drinking | Yes (before filter) | 6 | 3 | 29.9–≥2419.6 * | 1.0–24.6 | Galvanized | Polyethylene | Yes | Yes |
Yes (after filter) | 4 | 1 | 8.6–≥2419.6 * | <1.0–2.0 | ||||||
12 | Gardening | No | 8 | 6 | 151.5–≥2419.6 * | 3.2–111.2 | Tiles | Galvanized | Yes | Yes |
13 | Gardening | No | 8 | 7 | 83.6–≥2419.6 * | 6.0–648.8 | Tiles | Polyethylene | No | Yes |
14 | Gardening | No | 6 | 3 | 4.1–1986.3 | 4.1–38.9 | Tiles | Galvanized | Yes | No |
15 | Gardening | No | 6 | 5 | 24.6–1203.3 | 1.0–33.1 | Tiles | Galvanized | Yes | No |
16 | Gardening | No | 6 | 4 | 18.5–1119.9 | 1.0–517.2 | Tiles | Galvanized | Yes | No |
17 | Toilets flushing | No | 8 | 2 | 22.9–307.6 | 1.0–2.0 | Galvanized | Galvanized | No | No |
18 | Toilets flushing | No | 8 | 8 | 14.4–259.5 | 1.0–27.5 | Galvanized | Polyethylene | No | No |
19 | Toilets flushing | No | 8 | 6 | 179.3–1413.6 | 2.0–461.1 | Tiles | Polyethylene | No | No |
20 | Toilets flushing | No | 8 | 6 | 142.1–1299.9 | 3.1–1203.3 | Tiles | Polyethylene | No | No |
21 | Toilets flushing | No | 8 | 6 | 165.0–≥2419.6 * | 1.0–1986.3 | Tiles | Polyethylene | No | No |
22 | Toilets flushing | No | 6 | 2 | 17.5–107.6 | 9.7–14.8 | Tiles | Polyethylene | Yes | No |
23 | Toilets flushing | Yes | 8 | 6 | 18.9–≥2419.6 * | 2.0–435.2 | Galvanized | Polyethylene | No | No |
24 | Toilets flushing | No | 5 | 1 | 16.4–≥2419.6 * | 1.0–107.1 | Galvanized | Polyethylene | No | Yes |
25 | Toilets flushing | No | 6 | 4 | 119.9–≥2419.6 * | 2.0–18.7 | Galvanized | Galvanized | No | No |
26 | Toilets flushing | No | 8 | 8 | 27.5–≥2419.6 * | 1.0–≥2419.6 * | Galvanized | Polyethylene | No | No |
27 | Firefighting | No | 6 | 1 | 5.2–1986.3 | 1.0–325.5 | Galvanized | Polyethylene | Yes | No |
28 | Unused | No | 6 | 6 | 13.5–1299.7 | 1.0–58.6 | Tiles | Galvanized | Yes | Yes |
* Count that exceeded the quantitation limit of 2416.9 MPN/100 mL in the IDEXX Quanti-Tray*/2000 Most Probable Number Table. * Not inclusive of samples that contained < 1.0 MPN, and samples only positive to total coliforms.