Number of samples found positive to total coliforms and E. coli in some tank.

Tank Number Rainwater Use Filter on Tank Positive to Total Coliforms/8 Samples Positive to E. coli/8 Samples Total Coliforms: Minimum and Maximum Detection E. coli: Minimum and Maximum Detection Roof Material Tank Material TV Antenna on Rooftop Hanging Canopy
1 Drinking No 8 6 18.5–2419.6 1.0–59.1 Galvanized Galvanized Yes No
2 Drinking Yes (before filter) 8 6 1046.2–613.1 866.4–461.1 Galvanized Polyethylene Yes No
Yes (after filter) 8 5 28.8–365.4 1.0–13.4
3 Drinking Yes (before filter) 7 4 58.6–≥2419.6 11.0–365.4 Galvanized Polyethylene Yes No
Yes (after filter) 5 2 42.6–866.4 1.0–5.2
4 Drinking No 8 5 1.0–≥2419.6 * 1.0–980.4 Galvanized Polyethylene Yes No
5 Drinking Yes (before filter) 8 7 140.8–≥2419.6 * 13.2–1986.3 Tiles Polyethylene No Yes
Yes (after filter) 7 5 172.3–648.8 2.0–50.4
6 Drinking No 8 6 5.2–≥2419.6 * 1.0–7.2 Tiles Polyethylene Yes Yes
7 Drinking Yes (before filter) 8 5 1.0–≥2419.6 * 1.0–≥2419.6 * Galvanized Galvanized No Yes
Yes (after filter) 6 3 1.0–≥2419.6 * 1.0–≥2419.6 *
8 Drinking No 6 3 2.0–≥2419.6 * 1.0–39.3 Galvanized Concrete No No
9 Drinking Yes (before filter) 8 3 256.5–≥2419.6 * 2.0–22.8 Galvanized Polyethylene Yes No
Yes (after filter) 2 1 24.3–1553.1 <1.0–1.0
10 Drinking Yes (before filter) 6 3 32.7–1986.3 13.4–648.8 Galvanized Polyethylene Yes Yes
Yes (after filter) 3 2 3.0–88.2 1.0–11.0
11 Drinking Yes (before filter) 6 3 29.9–≥2419.6 * 1.0–24.6 Galvanized Polyethylene Yes Yes
Yes (after filter) 4 1 8.6–≥2419.6 * <1.0–2.0
12 Gardening No 8 6 151.5–≥2419.6 * 3.2–111.2 Tiles Galvanized Yes Yes
13 Gardening No 8 7 83.6–≥2419.6 * 6.0–648.8 Tiles Polyethylene No Yes
14 Gardening No 6 3 4.1–1986.3 4.1–38.9 Tiles Galvanized Yes No
15 Gardening No 6 5 24.6–1203.3 1.0–33.1 Tiles Galvanized Yes No
16 Gardening No 6 4 18.5–1119.9 1.0–517.2 Tiles Galvanized Yes No
17 Toilets flushing No 8 2 22.9–307.6 1.0–2.0 Galvanized Galvanized No No
18 Toilets flushing No 8 8 14.4–259.5 1.0–27.5 Galvanized Polyethylene No No
19 Toilets flushing No 8 6 179.3–1413.6 2.0–461.1 Tiles Polyethylene No No
20 Toilets flushing No 8 6 142.1–1299.9 3.1–1203.3 Tiles Polyethylene No No
21 Toilets flushing No 8 6 165.0–≥2419.6 * 1.0–1986.3 Tiles Polyethylene No No
22 Toilets flushing No 6 2 17.5–107.6 9.7–14.8 Tiles Polyethylene Yes No
23 Toilets flushing Yes 8 6 18.9–≥2419.6 * 2.0–435.2 Galvanized Polyethylene No No
24 Toilets flushing No 5 1 16.4–≥2419.6 * 1.0–107.1 Galvanized Polyethylene No Yes
25 Toilets flushing No 6 4 119.9–≥2419.6 * 2.0–18.7 Galvanized Galvanized No No
26 Toilets flushing No 8 8 27.5–≥2419.6 * 1.0–≥2419.6 * Galvanized Polyethylene No No
27 Firefighting No 6 1 5.2–1986.3 1.0–325.5 Galvanized Polyethylene Yes No
28 Unused No 6 6 13.5–1299.7 1.0–58.6 Tiles Galvanized Yes Yes

* Count that exceeded the quantitation limit of 2416.9 MPN/100 mL in the IDEXX Quanti-Tray*/2000 Most Probable Number Table. * Not inclusive of samples that contained < 1.0 MPN, and samples only positive to total coliforms.