Skip to main content
. 2016 Mar 8;17(2):139–144. doi: 10.1120/jacmp.v17i2.5980

Table 1.

Treatment planning objectives for VMAT and IMRT plans

Target Dose—Volume Constraints Weight
PTV Min dose 50 Gy, to 98% volume 100
Max dose 53 Gy 100
Uniform dose 50.5 Gy 100
Normal Tissue Dose—Volume Constraints Weight
Spinal cord No portion may receive 45 Gy 75
Contralateral lung
V5<40%
10
Whole lung
V5<60%
15
V20<28%
13
V30<20%
10
Heart
V30<40%
10
Ring Max dose <51Gy 10