Skip to main content
. 2017 Aug 30;18(5):245–250. doi: 10.1002/acm2.12165

Table 1.

Clinical goals for head and neck planning

Structure Dosimetric goal Dosimetric parameter
PTV HR ≥6000 cGy V95%
PTV HR ≥5550 cGy V99%
PTV HR 0.75 Conformity indexa
PTV SR ≥5400 cGy V95%
PTV SR ≥5022 cGy V99%
PTV SR 0.75 Conformity indexa
Brainstem + 3 mm ≥5400 cGy Dose to 0.1 cc
Cochlea + 3 mm (applies to both cochleas) ≥4500 cGy Mean dose
Cord + 3 mm ≥5000 cGy Dose to 0.1 cc
Larynx + 3 mm ≥4100 cGy Mean dose
Larynx + 3 mm ≥6000 cGy D24%
Normal Tissue (skin minus PTV SR) ≥5940 cGy D1%
Contralateral Parotid + 3 mm ≥2600 cGy Mean dose
Contralateral Parotid + 3 mm ≥3000 cGy D50%
Contralateral Submandibular + 3 mm ≥3500 cGy Mean dose
a