Table 3.

Univariate Classification of Human Osteochondral Plugs by OARSI Grade.

Training Set Validation Set


ROI MRI Measurement Sensitivity Specificity Accuracy Sensitivity Specificity Accuracy
Superficial DW (b = 2000 s/mm2) 0.76 ± 0.00 0.60 ± 0.04 0.68 ± 0.02 0.75 ± 0.02 0.59 ± 0.04 0.67 ± 0.03
MTR 0.58 ± 0.01 0.75 ± 0.04 0.67 ± 0.02 0.58 ± 0.02 0.73 ± 0.05 0.66 ± 0.03
T2 3D (ms) 0.62 ± 0.07 0.71 ± 0.04 0.67 ± 0.04 0.58 ± 0.07 0.69 ± 0.06 0.63 ± 0.04
Deep T1W 0.70 ± 0.02 0.67 ± 0.04 0.68 ± 0.02 0.68 ± 0.04 0.67 ± 0.05 0.67 ± 0.03
MTR 0.52 ± 0.06 0.76 ± 0.04 0.64 ± 0.04 0.51 ± 0.06 0.76 ± 0.04 0.64 ± 0.04
T2W (TE = 70 ms) 0.61 ± 0.03 0.65 ± 0.06 0.63 ± 0.05 0.56 ± 0.06 0.65 ± 0.06 0.61 ± 0.05
Full T1W 0.75 ± 0.02 0.66 ± 0.05 0.71 ± 0.03 0.73 ± 0.04 0.64 ± 0.06 0.69 ± 0.05
T2 3D (ms) 0.58 ± 0.02 0.77 ± 0.04 0.68 ± 0.02 0.53 ± 0.02 0.77 ± 0.04 0.65 ± 0.02
MTR 0.53 ± 0.01 0.78 ± 0.04 0.65 ± 0.03 0.53 ± 0.02 0.78 ± 0.04 0.65 ± 0.03

Univariate classification of human osteochondral plugs grouped by OARSI grade for the top three performing MRI measurements in superficial, deep, and full-thickness ROIs. Sensitivity, specificity, and accuracy are reported as the means and standard deviations over 100 random selections of training sets and validation sets of equal size normal (n = 23) and diseased (n = 17) groups using the Mahalanobis distance metric and leave-one-out cross-validation method.