Skip to main content
. Author manuscript; available in PMC: 2019 Mar 1.
Published in final edited form as: Optom Vis Sci. 2018 Mar;95(3):223–233. doi: 10.1097/OPX.0000000000001186

Table 1.

Descriptive statistics measured over the duration of each experimental condition and within each experimental group.

Group 1
(Children – Symbols)
Group 2
(Children – Text)
Adults
(Text)
Passive
(n = 31)
Active
(n=30)
Passive
(n=23)
Active
(n=23)
Passive
(n=8)
Active
(n=8)
Age* (years) 5.0(1.0) 5.1(1.1) 7.5(1.2) 25.3(2.8)
Spherical Equivalent Refractive Error* (D) +1.49(0.95)
min=−0.37; max=+4.19
+1.38(1.00)
min=−0.37; max=+4.19
+1.15(1.19)
min = −0.25; max = +4.58
+0.65(0.42)
min = −0.13; max = 1.15
Accommodative* Lag (D) 1.54(0.39) 1.32(0.45) 1.42(0.53) 1.23(0.37) 1.14(0.32) 1.15(0.36)
Total Accommodative Response* (D) 2.95(1.03) 3.06(1.21) 2.73(1.29) 2.92(1.28) 2.51(0.39) 2.50(0.39)
RMSˆ (D) 0.59 (0.39, 0.80) 0.31 (0.28, 0.43) 0.33 (0.26, 0.44) 0.26 (0.22, 0.34) 0.27 (0.22, 0.41) 0.22 (0.18, 0.34)
LFCˆ (Hz) 1.28E-03
(5.9E-4, 2.4E-03)
3.83E-04
(2.2E-04, 5.9E-04)
3.23E-04
(1.7E-04, 6.2E-04)
1.93E-04
(1.1E-04, 3.0E-04)
1.68E-04
(1.1E-04, 4.7E-04)
1.1E-04
(6.9E-05, 2.6E-04)
Pupil Size (mm) 5.8(0.7) 5.9(0.7) 5.9(0.8) 6.1(0.6) 5.0(0.6) 5.6(1.0)

RMS – Root mean square; LFC – low-frequency component (0-0.6Hz); D – diopters; Hz – hertz; mm – millimeters

*

Values are reported as mean(standard deviation)

ˆ

Values are reported as median and interquartile range

Significant difference between mean refractive error of combined Groups 1 & 2 and the adults (two sample t-test, P = 0.0032)