Table 3.

Simulation results when the length of the acquisition is varied. Shown are the k-means centroids for the fully sampled simulation data, at a fixed SNR of 5.6 (compare with the results in Table 1). The length of the signals and the dictionary were varied from 250 time points up to 2000, where the results in Table 1 correspond to signal length of 3000 time points.

Length 250 500 1000 2000
T1 T2 Weight T1 T2 Weight T1 T2 Weight T1 T2 Weight T1 T2 Weight
800 60 0.5 1037.8 91.2 0.98 1018.76 86.4 0.83 991.9 83.9 0.79 960.1 82.4 0.73
1300 120 0.5 1084.3 442.9 0.02 1147.8 117.0 0.17 1221.8 118.9 0.21 1267.8 113.7 0.27
800 60 0.5 956.3 22.5 0.11 986.8 75.1 0.35 899.8 70.7 0.43 881.9 75.9 0.49
1700 180 0.5 1229.1 135.4 0.89 1348.0 150.1 0.65 1484.0 156.0 0.57 1609.8 159.0 0.51
1700 180 0.5 1968.6 418.7 0.55 1914.2 165.6 0.45 1897.1 194.7 0.70 1944.5 196.3 0.70
2950 500 0.5 2051.1 180.3 0.45 2109.9 393.9 0.55 2459.6 485.6 0.30 2684.7 486.3 0.30
800 60 0.9 878.9 54.9 0.64 898.0 72.4 0.94 888.7 73.4 0.97 873.6 72.8 0.96
1700 180 0.1 950.3 127.1 0.36 1072.5 115.8 0.06 1403.8 146.3 0.03 1284.3 107.5 0.04