Skip to main content
. 2018 Mar 4;18(3):779. doi: 10.3390/s18030779

Table 2.

Parameters of the specimens.

Specimen No. Wave Velocity in Steel Bolt (m/s) Steel Bolt Diameter (mm) Steel Bolt Length (mm) PVC Pipe Diameter (mm) Concrete Class Defect Location (mm)
1 5100 30 3700 100 C30 3100
2 5100 30 6000 100 C30 1800 and 4100