Summary of the strain sensitivity analyses conducted on cured nanocomposite cement paste specimens, including Gauge Factors (GFs), and the hysteresis areas of the relative change in electrical resistance versus applied strain curves, considering both quasi-static and sine-sweep dynamic compression loads.

MWCNTs Content GF Hysteresis Area [µε]
(Quasi-Static Loading)
Hysteresis Area [µε]
(Sine-Sweep Loading)
0.00% 17 8.00 × 10−4 1.67 × 10−2
0.25% 2 4.09 × 10−3 3.17 × 10−3
0.50% 18 4.79 × 10−2 9.25 × 10−3
0.75% 8 4.89 × 10−3 2.46 × 10−3
1.00% 6 1.06 × 10−3 3.30 × 10−4
1.50% 12 2.67 × 10−3 2.52 × 10−3