Skip to main content
. 2018 Mar 7;12(1 Suppl):120–126. doi: 10.2101/Ajid.12v1S.18

Table 1.

The results of PCR and microscopy in detection of E. histolytica, E. dispar and E. moshkovskii complex

PCR* Microscopy Total

Positive (%) Negative (%)
Positive 10 (83.3) 2(16.7) 12 (100.0)
Negative 11 (61.1) 7 (38.9) 18 (100)
Total 21 (70.0) 9 (30.0) 30 (100)
*

Sensitivity 47.6%, specificity 77.7%, PPV 83.3%, NPV 38.9%, p=0.022 (McNemar test)