Skip to main content
. 2018 Mar 29;136(5):490–495. doi: 10.1001/jamaophthalmol.2018.0590

Table 3. Repeated-Measures Longitudinal Regression of Loge Visual Field Area on Model 1 Variablesa.

Coefficient Estimate (SE) 95% CI Degrees of Freedom t Value Probability >|t|
b0b 9.0416 (0.0987) 8.8449 to 9.2383 72 91.61 <.001
b1c 0.1282 (0.1196) −0.1102 to 0.3667 72 1.07 .29
b2d 0.0037 (0.0241) −0.0436 to 0.0511 424 0.15 .88
b3e 0.0204 (0.0283) −0.0353 to 0.0760 424 0.72 .47
a

Kinetic visual fields measured with the V4e white test light of the Goldmann perimeter on a white background of 31.5 apostilbs, scanned, and then converted to areas by custom software. Based on 74 patients and 500 observations analyzed by the MIXED procedure of SAS.

b

b0 indicates intercept for the control cohort at mean-centered time.

c

b1 indicates change in intercept at mean-centered time for the vitamin A cohort.

d

b2 indicates annual change in loge visual field area for the control cohort.

e

b3 indicates change in annual change in loge visual field area for the vitamin A cohort.