Skip to main content
. 2017 Oct 18;4:79–84. doi: 10.1016/j.pvr.2017.10.002

Table 1.

Comparison of input volumes of HPV genotyping assays.

HPV genotyping assay Nucleic acid extraction method Original sample input volume (mL) Elution volume (mL) PCR template volume (mL) Total post-PCR volume (mL) Total detection volume (mL) Fraction of original sample detected Equivalent original sample volume tested (mL)
This study:
Anyplex IIa MagNAPure 96 0.50a 0.05 0.005 0.01 0.01 0.1 0.05
Linear Arraya MagNAPure 96 1.00a 0.10 0.05 0.20 0.075 0.05 0.047b
EuroArraya MagNAPure 96 0.50 0.05a 0.005 0.09 0.065 0.01 0.007
Manufacturers’ recommendations:
Anyplex II various 1.00 0.05 – 0.10 0.005 0.01 0.01 0.05 – 0.10 0.05 – 0.10
Linear Array AmpliLute Liquid Media Extraction 0.25 0.10 0.05 0.20 0.075 0.05 0.012b
EuroArray QIAamp or NucleoSpin 0.50 0.06 – 0.10 0.005 0.09 0.065 0.007 – 0.012 0.004 – 0.006
a

Volumes apply to this study and are a deviation from the manufacturer's recommendations.

b

Extraction volumes have been validated to ensure equivalent sensitivity using DNA extracted by MagNAPure 32 automated system compared with the manufacturer-specified AmpliLute manual system.