Skip to main content
. 2018 Mar 13;114(5):1142–1152. doi: 10.1016/j.bpj.2017.12.045

Table 5.

Muscle Apparent Rate Constants for the Converter Line Fibers under Conditions that Generated Maximum Small Amplitude Power

A (kN/m2) k (unitless) B (kN/m2) 2πb (s−1) C (kN/m2) 2πc (s−1)
IFI-11a [10] 268 ± 23 0.137 ± 0.006d,e 3219 ± 312b,c,d,e 1996 ± 79b,c,d,e 3041 ± 296b,c,d,e 2780 ± 56d,e
IFI-11b [10] 277 ± 25 0.125 ± 0.005c,d 1053 ± 153a,c 987 ± 113a,c,d,e 888 ± 156a,c 3425 ± 443d,e
IFI-11c [12] 217 ± 24 0.147 ± 0.005b,d,e 2186 ± 251a,b,d,e 1729 ± 120a,b,d,e 2125 ± 261a,b,d,e 3228 ± 231d,e
IFI-11d [13] 315 ± 37 0.100 ± 0.005a,b,c 563 ± 68a,c 651 ± 42a,b,c 587 ± 64a,c 5452 ± 432a,b,c
IFI-11e [14] 321 ± 33 0.116 ± 0.005a,c 635 ± 70a,c 509 ± 22a,b,c 485 ± 40a,c 5553 ± 410a,b,c

All values are mean ± SE. Superscript letters after values in the tables indicate a statistically significant difference between that line and the converter line indicated. One-way ANOVA with Holm-Sidak pairwise multiple comparisons was used (SigmaPlot v11.0) with P < 0.05. Brackets indicate number of fibers tested.