Table 3.
Imaging protocol | Slice chosen | Measurement | Width (mm) in control | Width (mm) in bilateral SNHL | |
---|---|---|---|---|---|
Fatterpekar et al. [3] | Parallel to the infraorbitomeatal line | Slice at oval window | Manual measurement along the inner margin of its bony walls at its midportion | 2.13 ± 0.44 (N = 50 ears) |
1.82 ± 0.24 in profound bilateral SNHL (N = 33 ears) |
| |||||
Komatsubara et al. [10] | 30° downward to the orbitomeatal line | Slice with maximum width | Digital measurement at midline between two straight lines drawn on the fundus of the IAC and the base of the modiolus | 1.91 ± 0.27 (N = 100 ears) |
0.99 ± 0.37 (with CND) 1.73 ± 0.32 (with developed cochlear nerve) |
| |||||
Kono [11] | Parallel to the infraorbitomeatal line | n.a | Measurement at the base of the modiolus | 2.1 ± 0.2 (N = 118 ears) |
n.a |
| |||||
Stjernholm et al. [2] | Temporal bone cast using silicone rubber | n.a | Measurement in axiopetrosal plane | 2.58 ± 0.31 (N = 117 ears) | n.a |
Parallel to the infraorbitomeatal line | Slice at posterior semicircular canal | Measurement along the inner margin of its bony walls at its midportion | 1.91 ± 0.24 (N = 100 ears) | n.a | |
| |||||
Pagarkar et al. [12] | Direct scanning in axial plane spiral with a pitch of 1 | Slice with maximum width | Maximum width was measured to the nearest 0.1 mm | 1.9 ± 0.7 (N = 19 ears) | 1.0 ± 0.2 (N = 8 ears) |
| |||||
Teissier et al. [13] | Parallel to the lateral semicircular canal | Slice containing the cochlear modiolus, the oval window | Measurement at the entry of the cochlea | 2.16 ± 0.24 (N = 174 ears) | 2.12 ± 0.55 (N = 120 ears) |
BCNC: bony cochlear nerve canal; SNHL: sensorineural hearing loss; n.a: not available.