Skip to main content
. 2018 Jan 16;32(4):900–910. doi: 10.1038/leu.2017.340

Table 3. Quality control measurements.

Analyte     Lower limit of quantification Low QC Medium QC High QC
      10 nM 30 nM 300 nM 1000 nM
Dihydro-5-AZA-CdR   Average±s.d. 11.3±4.33 31±2.83 299±1.78 998±2.28
  Intra-day Accuracy (%) 96.7–103.4 99.9–101.6 99.8–100.2 99.76–100.1
    Precision (%) 0–8.7 2.1–2.2 1.1–1.8 0.30–0.37
  Inter-day Accuracy (%) 102.5 101.8 99.28 100.36
    Precision (%) 7.1 1.75 1.26 0.85
Dihydro-5-AZA     10 nM 50 nM 300 nM 1000 nM
    Average±s.d. 9.3±4.2 51±3.73 299±2.49 997±3.21
  Intra-day Accuracy (%) 93.3–102.4 102.7–105.1 99.45–99.98 100.1–100.8
    Precision (%) 6.11–9.25 4.8–9.3 0.53–1.1 0.74–5.82
  Inter-day Accuracy (%) 95.42 99.69 99.42 100.23
    Precision (%) 6.91 8.7 3.59 0.49

Abbreviations: AZA, 5-azacytidine; QC, quality control.