Table 2. Summary of prostate motion per timestamp on log files, the worst-case motion during tracking irradiation simulated in this study in the SI, RL, and AP directions and the 3D vector length.
Intra-fraction motion (mm) | Worst-case motion (mm) | |||||||
---|---|---|---|---|---|---|---|---|
SI | RL | AP | 3D vector length | SI | RL | AP | 3D vector length | |
Mean | −0.15 | −0.09 | 0.79 | 2.53 | 0.03 | −0.01 | −0.02 | 0.88 |
SD | 2.06 | 0.81 | 1.99 | 1.77 | 0.91 | 0.35 | 1.04 | 1.25 |
Max | 9.25 | 3.15 | 9.73 | 13.56 | 5.81 | 2.83 | 10.13 | 13.73 |
Min | −9.43 | −3.73 | −6.87 | 0.10 | −9.48 | −3.09 | −8.68 | 0.00 |
RMSE | 2.06 | 0.82 | 2.15 | - | 0.91 | 0.35 | 1.04 | - |
The sign of intra-fraction motion in the SI, RL, and AP directions is consistent with the coordinates in Fig 2.
SI, superior-inferior; RL, right-left; AP, anterior-superior; 3D, three-dimensional; SD, standard deviation; Max, maximum; Min, minimum; RMSE, root mean square error.