Skip to main content
. Author manuscript; available in PMC: 2018 Oct 1.
Published in final edited form as: J Environ Health. 2017 Oct;80(3):34–49.

Table 2.

Cumulative Bowl Water Clearance by Flush Number (Logs*)

Toilet Type and Suspension 4 Flushes 12 Flushes 24 Flushes
LO HI LO HI LO HI
PAT 0.25 μm FM 5.0 5.0 5.1 5.0
FOM 0.25 μm FM 5.4 5.7 6.0
HET 0.25 μm FM 5.9 5.0 7.0 -- 7.4
HET 0.5 μm FM 5.3 7.2 7.3
HET 1.0 μm FM 6.2 7.5 7.8
HET PF 4.5 5.4 5.2 5.8 5.5 6.0
FOM PF 5.1 5.6 5.6
FOM CD 8.0 8.9 ND
*

Calculated as log10 (1/fraction remaining after n flushes).

PAT = pressure-assisted toilet; FM = fluorescent polymer microspheres; FOM = flushometer toilet; HET = high efficiency gravity flow toilet; PF = Pseudomonas fluorescens; CD = Clostridium difficile; LO = lower flush volume; HI = higher flush volume; ND = none detected.