Skip to main content
. 2018 Apr 3;6:36. doi: 10.3389/fcell.2018.00036

Table 1.

Parameter values for Equations (1)–(5).

Parameter Value Definition
A 0.25 Calcium source
B 200 Strength of calcium induced calcium degradation
C 3, 125 Calcium release depending on all forms of calcium and IP3
D 7.5 Strength of IP3 blocking calcium degradation
E 0.00125 Calcium leakage
PLC 100 Strength of calcium induced IP3 release
ϵ 0.001 IP3 source
r 10 IP3 degradation
d 10 Diffusion rate
ud 0.5 Calcium degradation sensitivity to calcium
ed 2 Hill coefficient
ps 0.1 Calcium degradiation sensitivity to IP3
es 3 Hill coefficient
up 0.025 IP3 production sensitivity to calcium
ep 4 Hill coefficient
ub 2.25 Calcium degradation sensitivity to calcium
eb 2 Hill coefficient
vc 9 Calcium release sensitivity to stored calcium
ec 2 Hill coefficient
upa 0.45 Calcium release sensitivity to cytosolic calcium
epa 4 Hill coefficient
upi 1 Calcium release sensitivity to cytosolic calcium
epi 5 Hill coefficient
pc 0.1 Calcium release sensitivity to IP3
epc 2 Hill coefficient
L0 1.5 Calcium store spacing

All unit dimensions have been chosen to make u, v, and p have units of μMol, space is in μm and time is in seconds.