Published in final edited form as: J Surg Res. 2015 Jan 9;195(1):257–262. doi: 10.1016/j.jss.2014.12.051

Table 5.

The effect of examined clinical parameters on the ability to detect SpHb levels and the effect of vasopressor support and mechanical ventilation on the ability to detect SpHb levels.

Parameter Able to detect SpHb reading?
P value
Yes
No
Mean (95% CI) Mean (95% CI)
Age, y   6.8 (5.5–8.1)   7.7 (5.7–9.7)   0.4462
BMI, kg/m2 16.8 (15.8–17.8) 20.3 (18.7–21.9)   0.0005
Massey   3.2 (2.6–3.7)   3.2 (2.3–4.1)   0.9548
LabHb, g/dL 11.1 (10.7–11.5) 10.6 (9.9–11.3)   0.204
SpO2, % 97.9 (96.4–99.5) 91.3 (88.8–93.8) <0.0001
Temperature, C    37 (36.8–37.2) 36.6 (36.4–36.9)   0.0277
Mean BP, mm Hg 87.7 (65.7–109.6) 75.4 (39.9–110.8)   0.5585
PI   3.5 (0.0–7.0)   6.1 (4.0–8.2)   0.21
Vasopressor support, %    21 (25.3)    10 (28.6)   0.8193*
Mechanical ventilation, %    42 (50.6)    20 (57.1)   0.5504*
Total number of attempts    83    35

CI = confidence interval.

*

Fisher exact test.