Skip to main content
. Author manuscript; available in PMC: 2018 Dec 1.
Published in final edited form as: Am J Ophthalmol. 2017 Sep 28;184:63–74. doi: 10.1016/j.ajo.2017.09.020

Table 5.

Progression Detection Rate Stratified by Severity of Perimetric Glaucoma

Instrument Parameter Mild (N=111 ) Moderate (N= 27) Advanced (N= 15)
Optical Coherence Tomography Ganglion Cell Complex 44.1 48.2 46.7
(34.9, 53.4) (29.3, 67.0) (21.4, 71.9)
Nerve Fiber Layer 43.2 33.3 26.7
(34.0, 52.5) (15.6, 51.1) (4.3, 49.1)
Either Thickness 63.1 55.6 66.7
(54.1, 72.0) (36.8, 74.3) (42.8, 90.5)
Visual Field Visual Field Index Trend 26.1 33.3 40
(18.0, 34.3) (15.6, 51.1) (15.2, 64.8)
Mean Deviation Trend 27.0 37.0 26.7
(18.8, 35.3) (18.8, 55.3) (4.3, 49.1)
Event Analysis 15.3 29.6 33.3
(8.6, 22.0) (12.4, 46.9) (9.5, 57.2)
Any 38.7 48.2 53.3
(29.7, 47.8) (29.3, 67.0) (28.1, 78.6)

% progression detection rate (confidence interval)