Skip to main content
. 2018 Apr 12;13(4):e0195828. doi: 10.1371/journal.pone.0195828

Table 5. GFR (in ml/min/1.73m2) before, 24 hours after and 48h after contrast media application.

GFR before CM GFR 24hrs after CM GFR 48hrs after CM
N M ± SD p N M ± SD p N M ± SD p
MARE No 271 68.07 ± 30.96 0.14 250 72.19 ± 32.23 0.12 85 71.09 ± 30.03 0.001
Yes 18 62.12 ± 40.38 16 61.91 ± 50.59 8 14.04 ± 23.20
Dialysis No 277 68.80 ±31.72 0.06 255 71.35 ± 32.77 0.03 88 72.18 ± 30.69 0.003
Yes 12 55.85± 31.90 11 17.51 ± 39.14 5 11.27 ± 3.94
Death No 280 68.43 ± 32.57 0.09 258 71.51 ± 33.47 0.06 87 71.09 ± 32.29 0.002
Yes 9 63.11 ± 29.9 8 59.69 ± 46.97 6 24.04 ± 23.21

GFR—glomerular filtration rate according to the MDRD formula, MARE—major adverse renal event; N—number of patients, M—median, SD—standard deviation, p—significance according to MANOVA, p<0.05 is statistically significant.