Table 6.

Summary of Findings from Review of 4 of 18 Test Battery Studies (20 articles) Making Use of Nonspeech Measures of Central Auditory Processing

Test battery
study # (from
Table 4)
Nonspeech measures included in study Reported
age effects?
Reported
hearing
loss effects?
Reported
cognitive
effects?
Reported age
effect with
control for
hearing loss?
  7 Duration and frequency tone patterns Yes No NA Yes
  8 Auditory filter width at 1000 Hz, broadband noise gap detection, interaural time difference (ITD) discrimination for clicks centered at 500 and 2000 Hz Yes Yes NA Yes
11 Temporal order for midfrequency pure tones, 1000 Hz pure-tone duration discrimination Yes No Yes Yes
14 Pitch Pattern Sequence (PPS) Test and Random Gap Detection Test (RGDT); RGDT data later excluded Yes No No Yes
Summary: # “Yes”/# of studies examining effect 4/4 1/4 1/2 4/4