Skip to main content
. 2017 Aug 23;13(6):599–606. doi: 10.1002/cmdc.201700303

Table 1.

Descriptor results for all compounds.

Descriptor changed
Dataset[a]
# of samples Mean descriptor change ΔT m/Δdescriptor [°C] ±SEM [°C] p value[b]
Fluorine atoms
PATENTS dataset
Schultes In‐House
Karthikeyan

17 297
24
41

1.29
1.3
1.8

1.2
−0.77
−3.9

±0.3
±7.3
±7.7

<0.0001
n.s.
n.s.
Chlorine atoms
PATENTS dataset
Schultes In‐House
Karthikeyan

9893
9
188

1.04
1.0
1.0

6.2
−10
7.0

±0.4
±14
±3.4

<0.0001
n.s.
<0.05
Bromine atoms
PATENTS dataset
Schultes In‐House
Karthikeyan

2804
16
128

1.02
1.0
1.2

14
47
20

±0.8
±9.0
±4.1

<0.0001
<0.001
<0.0001
Iodine atoms
PATENTS dataset
Schultes In‐House
Karthikeyan

400
1
8

1.02
1.0
1.0

20
10
39

±2.2
NA
±3.2

<0.0001
n.s.
<0.05
H‐bond donors
PATENTS dataset
Schultes In‐House
Karthikeyan

12 889
36
46

1.02
1.1
1.1

23
44
25

±0.5
±7.7
±9.0

<0.0001
<0.0001
<0.05
H‐bond acceptors
PATENTS dataset
Schultes In‐House
Karthikeyan

24 358
13
263

1.16
1.0
1.7

11
36
12

±0.3
±13
±3.1

<0.0001
<0.05
<0.0001
Rotatable bonds
PATENTS dataset
Schultes In‐House
Karthikeyan

68 531
61
155

1.27
1.3
2.0

−7.3
−16
−6.0

±0.2
±4.9
±4.3

<0.0001
<0.0001
<0.001
logP calc
PATENTS dataset
Schultes In‐House
Karthikeyan

24 818
103
390

0.92
0.5
0.7

4.6
−2.0
2.9

±0.4
±3.7
±2.2

<0.0001
n.s.
n.s.

[a] The PATENTS dataset comprises the ∼275 000 compound dataset we used in the study; the Schultes In‐House and Karthikeyan datasets are those used in the Schultes study.16 [b] n.s.=non‐significant (p>0.05).