Skip to main content
. 2017 Nov 6;66(9):1419–1426. doi: 10.1093/cid/cix988

Table 2.

Diagnostic Accuracy Evaluation of Sputum Auramine Smear and Xpert MTB/RIF Assay by the Reference Standard of Positive Culture From Any Site (n = 255) Among 484 Seriously Ill Human Immunodeficiency Virus–Infected Participants Presenting With a Cough of Any Duration and ≥1 World Health Organization Danger Sign

Parameter Xpert MTB/RIF Auramine Smear
Sensitivity, % 86.3 (81.5–90.3) 57.0 (50.7–63.2)
Specificity, % 96.1 (92.6–98.2) 98.7 (96.2–99.7)
Positive predictive value, % 96.1 (92.7–98.2) 98.0 (94.2–99.6)
Negative predictive value, % 86.2 (81.4–90.2) 67.2 (61.9–72.2)
Positive likelihood ratio 21.9 (11.5–41.6) 43.3 (14.0–134.0)
Negative likelihood ratio 0.14 (.11–.19) 0.44 (.38–.50)

Values in parentheses indicate the 95% confidence interval.