TABLE V.

Performance evaluation as a function of the patch size

Input size Recall Precision F-Score Over-detected
31 × 31 0.7120 0.6970 0.7039 0.0965
41 × 41 0.9170 0.7763 0.8408 0.0880
51 × 51 0.8104 0.8820 0.8447 0.0600
61 × 61 0.8552 0.7916 0.8222 0.0816
71 × 71 0.6192 0.8420 0.6645 0.0716