Skip to main content
. 2016 Nov 8;67(6):699–709. doi: 10.1007/s12576-016-0499-3

Table 2.

Heart rate and systemic arterial blood pressure responses associated with each condition

Heart and blood pressure measures Baseline SPLN stimulation CST section CST section + SPLN stimulation
HR (beats/min) 433 ± 8 438 ± 8 444 ± 12 438 ± 8
Systolic SABP (mmHg) 141 ± 5 122 ± 6* 134 ± 5 123 ± 8
Diastolic SABP (mmHg) 89 ± 4 75 ± 4* 85 ± 4 77 ± 5
Mean SABP (mmHg) 106 ± 4 91 ± 4* 101 ± 4 92 ± 6

Values in table are given as the mean ± standard error of the mean (SEM)

SPLN Splanchnic nerve, CST cervical sympathetic trunk, HR heart rate, SABP systemic arterial blood pressure