Skip to main content
. Author manuscript; available in PMC: 2019 May 1.
Published in final edited form as: Ear Hear. 2018 May-Jun;39(3):605–614. doi: 10.1097/AUD.0000000000000520

Figure 7.

Figure 7

The influence of signal level and frequency on the parameters obtained from equation 4 and quantified by equations 57. Parameter a reflects the amplitude of the reflex and grows similarly for the three frequencies. Parameter b represents the decay. There were significant differences between the three frequencies. Although 3 and 16 kHz differed from each other, they did not change significantly with signal level. Decay at 10 kHz, however, was influenced by signal level. The parameter c, estimates the rise time of the MEM reflex. The rise time at 3 kHz was not effected by signal level whereas at 10 and 16 kHz, the rise time was greatly influenced by signal level.