Skip to main content
. 2018 Apr 26;13:1343–1351. doi: 10.2147/COPD.S156168

Table 4.

6MWT parameters

COPD
(n = 12)
COPD+OSAS
(n = 12)
P-value
Rest
SBP (mmHg) 118 ± 10 129 ± 9 0.01*
HR (bpm) 82 ± 11 79 ± 13 0.56
SpO2 93 ± 3 95 ± 3 0.13
BORG D 0 ± 1 0 ± 0 0.10
BORG P 0 ± 1 0 ± 1 0.75
Peaks
SBP (mmHg) 147 ± 15 159 ± 25 0.17
HR (bpm) 104 ± 17 106 ± 13 0.72
SpO2 87 ± 9 91 ± 4 0.21
BORG D 3 ± 2 2 ± 1 0.04*
BORG P 4 ± 3 1 ± 1 0.01*
Covered distance
CD predicted (m) 557.17 ± 38.48 571.58 ± 41.42 0.38
CD reached (m) 362.12 ± 123.14 419.04 ± 77.66 0.18
% predicted 64.58 ± 20.03 73.45 ± 13.54 0.21
CDR COPD 1 and 2/CDR COPD+OSAS 3 and 4 320 ± 137 448 ± 33.05 0.18
CDR COPD 3 and 4/CDR COPD+OSAS 1 and 2 394 ± 114 409 ± 87 0.76

Notes:

*

Significant difference between groups (unpaired t-test). The variables are presented as mean ± SD.

Abbreviations: 6MWT, 6-minute walk test; COPD, chronic obstructive pulmonary disease; OSAS, obstructive sleep apnea syndrome; SBP, systolic blood pressure; HR, heart rate; SpO2, peripheral oxygen saturation; BORG D, dyspnea Borg Scale; BORG P, leg discomfort Borg Scale; CD, covered distance; CDR, covered distance reach.