Table 4. Diagnostic performance of disseminated intravascular coagulation (DIC) diagnostic classifiers in this study.

Dataset DIC criteria DIC Non-DIC AUC
(95% CI)
Diagnostic performance (95% CI)
Sensitivity (%) Specificity (%) PPV (%) NPV (%) Positive
LR
Negative
LR
Set 1
(n = 656)
ANN* 0.981
(0.973–0.989)
89.9
(85.3–93.5)
96.0
(93.7–97.7)
92.3
(88.3–95.1)
94.7
(92.4–96.3)
22.64
(14.18–36.14)
0.11
(0.07–0.15)
Positive 205 17
Negative 23 411
ISTH 0.945
(0.929–0.962)
82.0
(76.4–86.8)
93.7
(91.0–95.8)
87.4
(82.7–90.9)
90.7
(88.1–92.8)
13.00
(8.98–18.82)
0.19
(0.15–0.25)
Score ≥ 5 187 27
Score < 5 41 401
JMHW 0.943
(0.927–0.959)
91.2
(86.8–94.6)
84.4
(80.6–87.7)
75.6
(71.3–79.5)
94.8
(92.2–96.5)
5.83
(4.66–7.29)
0.10
(0.07–0.16)
Score ≥ 7 208 67
Score < 7 20 361
JAAM 0.928
(0.909–0.946)
94.7
(91.0–97.3)
79.0
(74.8–82.7)
70.6
(66.6–74.3)
96.6
(94.2–98.0)
4.51
(3.74–5.43)
0.07
(0.04–0.12)
Score ≥ 4 216 90
Score < 4 12 338
Set 2
(n = 217)
ANN* 0.968
(0.945–0.986)
90.0
(81.2–95.6)
93.4
(87.9–97.0)
88.9
(80.9–93.8)
94.1
(89.2–96.9)
13.7
(7.25–25.87)
0.11
(0.06–0.22)
Positive 72 9
Negative 8 128
ISTH 0.946
(0.916–0.976)
82.5
(72.4–90.1)
95.6
(90.7–98.4)
91.7
(83.3–96.0)
90.3
(85.3–93.8)
18.84
(8.56–41.46)
0.18
(0.11–0.29)
Score ≥ 5 66 6
Score < 5 14 131

ANN, artificial neural network; ISTH, the International Society on Thrombosis and Haemostasis; JMHW, the Japanese Ministry of Health and Welfare; JAAM, the Japanese Association for Acute Medicine; CI, Confidence Interval; AUC, area under curve; PPV, positive predictive value; NPV, negative predictive value; LR, likelihood ratio.