Skip to main content
. 2018 Apr 16;7:e33067. doi: 10.7554/eLife.33067

Table 2. Small-angle X-ray scattering (SAXS) data.

Data-collection parameters
 Instrument: ESRF BM29
 Wavelength (Å) 0.99
 q-range (Å−1) 0.0032–0.49
 Sample-to-detector distance 2.867 m
 Exposure time (sec/frame) 1
 Temperature (K) 283
 Detector Pilatus 1M (Dectris)
 Flux (photons/s) 1 × 1012
 Beam size (µm2) 172 × 172
Structural parameters IFT80 IFT80(BP1-BP2) IFT80
 Type of experiment SEC SAXS SEC SAXS Concentration series Concentration series
 Concentration used (mg/mL) 2 2 0.47–7.5 0.5–8.0
 NaCl concentration (mM) 150 500 150 150
 From* Rg (Å) 38.7 34.7 26.2 41.4–55.7
 p(r)*  Dmax (Å) 122 114 86.1 140.4–194.4
 Porod volume Vp x103 (Å3) 210.8 119.8 94.3 216–347
 Molecular mass (kDa) from Vp 131.8 74.8 58.9 126–202
 Molecular mass (kDa) from sequence 170 (dimer) 85 (monomer) 65 85
Modeling
 Dammif NSD 0.597 0.795

*distance distribution function.

†normalized spatial discrepancy between the 10 calculated models.