Skip to main content
. 2018 May 2;8:6882. doi: 10.1038/s41598-018-25231-z

Table 2.

Data collection and scattering-derived parameters.

Data collection parameters
WT Q383A
Beamline ESRF BM29
Beam geometry (mm2) 0.7 × 0.7
Wavelength (Å) 1.0
Q range (Å−1) 0.0025–0.5
No. of frames 10 20
Exposure time per frame (seconds)1 0.5 1
Samples concentrations (mg/ml) 4.1, 1.6, 1.1 0.9, 0.43, 0.2
Temperature (°C) 5
Structural parameters
Rg (Å) [from P(r)]1 22.6 ± 0.004 26.3 ± 0.01
Rg (Å) (from Guinier)1 22.4 ± 0.1 25.8 ± 0.4
Dmax (Å)2 75 ± 8 85 ± 9
Porod volume [from P(r)] (103 Å3) 42.53 50.75
NSD3 0.77 ± 0.04 0.55 ± 0.05
χ2 CRYSOL 3.8 5.2
χ2 EOM 1.0 1.1
Software employed
Primary data reduction AUTOMAR
Data processing PRIMUS
Modelling DAMMIF, EOM

1±S.E.

2±10% (estimated range).

3NSD, normalized shape discrepancy for DAMMIF calculation.