Table 1.

Data collection and processing

Diffraction source LCLS XFEL source (XPP Endstation)
Wavelength (Å) 1.29
Temperature (K) 293
Detector Rayonix MX170-HS CCD
Crystal-detector distance (mm) 340
Exposure time per image (s) 0.1
Space group P21 21 21
a, b, c (Å) 38.13, 46.48, 84.52
α, β, γ (°) 90.00, 90.00, 90.00
Resolution range (Å) 33.43-1.9
Images merged 8957
No. of unique reflections 12354
Completeness (%) 100
I/σ(I)〉 6.0
Multiplicity 51.6
Rsplit(%) 10.1(46.1)
Matthew’s coefficient, VM3/Da) 2.18
Solvent content, Vs (%) 43.5
Observations per image to edge of detector 166 ± 28
CC1/2 (%) 99.6 (42.6)