formulation XPS (C 1s spectra)
particle size (μm) % surface composition (theoretical) % surface composition (measured) ToF-SIMS (% normalized counts)




D10 D50 D90 naproxen PVPVA naproxen PVPVA m/z 231 (naproxen) m/z 112 (PVPVA)
 Batch 1 0.1 ± 0.0 0.5 ± 0.2 1.1 ± 0.1 54 46 12 ± 2 88 ± 2 0.008 ± 0.002 0.025 ± 0.002
 Batch 2 0.1 ± 0.1 0.5 ± 0.1 1.0 ± 0.1 54 46 9 ± 2a 91 ± 2a 0.003 ± 0.001b 0.025 ± 0.001