Skip to main content
. 2018 May 8;8:7304. doi: 10.1038/s41598-018-25547-w

Table 2.

Comparison of cardiac scintigraphy results in patients with narcolepsy type 1 (NT1) and rapid eye movement sleep behavior disorder (RBD) and in patients with idiopathic RBD (iRBD).

Variable NT1 with RBD n = 34 iRBD n = 15 Model 0 Model 1
n % n % OR [95% CI] p OR [95% CI] p
Delayed H/M ratioa,b 1.70 (1.20; 2.29) 1.29 (1.03; 1.68) 2.32 [1.42–3.80] 0.0008 2.07 [1.23–3.49] 0.006
Delayed H/M ratio
<1.40c 4 11.76 12 80.00 30.00 [5.82–154.63] <0.0001 14.02 [2.31–85.03] 0.004
≥1.40 30 88.24 3 20.00 1 1
Early H/M ratioa,b 1.64 (1.40; 2.29) 1.35 (1.08; 1.73) 3.05 [1.49–6.24] 0.002 2.44 [1.19–5.00] 0.02
MIBG washout %a,d 32.00 (24.00; 50.00) 38.00 (24.00; 56.00) 2.02 [0.85–4.79] 0.11 1.21 [0.46–3.19] 0.70

aContinuous variables are expressed as median (minimal value; maximal value).

bOR for 0.10-unit decrease.

cLowest tertile of the sample vs the other two.

dOR for 10-unit decrease.

Model 0: crude association.

Model 1: adjustment for age.