Abstract
Corrosion in carbonated concrete is an example of corrosion in dense porous media of tremendous socio-economic and scientific relevance. The widespread research endeavors to develop novel, environmentally friendly cements raise questions regarding their ability to protect the embedded steel from corrosion. Here, we propose a fundamentally new approach to explain the scientific mechanism of corrosion kinetics in dense porous media. The main strength of our model lies in its simplicity and in combining the capillary condensation theory with electrochemistry. This reveals that capillary condensation in the pore structure defines the electrochemically active steel surface, whose variability upon changes in exposure relative humidity is accountable for the wide variability in measured corrosion rates. We performed experiments that quantify this effect and find good agreement with the theory. Our findings are essential to devise predictive models for the corrosion performance, needed to guarantee the safety and sustainability of traditional and future cements.
Introduction
Corrosion of metals in porous media is a phenomenon that occurs in a variety of conditions, including metals in contact with soils1, in transportation and storage of granular materials2,3, or in timber4,5. Another example of particular scientific and practical relevance is corrosion of reinforcing steel in concrete. This is because reinforced concrete is worldwide among the most widely used materials6. Although generally durable in many different exposure conditions, corrosion of the reinforcing steel embedded in the cement-based material is the most frequent cause of premature degradation7,8 and causes high costs, comparable to those related to weather and climate disasters9. The pore system of concrete presents a unique environment to the steel, both in terms of pore size distribution – pore sizes ranging over several orders of magnitude and reaching down to the nanometer scale10 –, and in terms of electrolyte chemistry, that is, electrolyte of high ionic strength and highly alkaline pH11.
A relevant cause for corrosion of steel in concrete is carbonation of the concrete7, that is, the loss of alkalinity. In sound concrete, pH values are initially in the range of 12.5–146,7. Upon chemical reactions of the cement paste with carbon dioxide, penetrating the pore system of the concrete from the exposure environment, the pH may decrease to levels around 8–912. It is well known that this leads to a relatively uniform type of corrosion attack on the reinforcing steel7.
The mechanism governing the rate of this corrosion process has been subject to investigations since the 1950s13,14. A number of different hypotheses have been suggested including kinetic control related to the electrical resistivity (inverse of conductivity) of the concrete or the limited availability of oxygen at the steel surface – that both correlate with the moisture state of the concrete pore system. There is however, no consensus on the mechanistic understanding. This is one of the main reasons for the general lack of reliable, quantitative models for the prediction of corrosion rates in carbonated concrete14, which presents a severe obstacle for holistic life cycle assessments of both traditional and novel building materials.
The question of corrosion rates in carbonated concrete is, after having been addressed for over half a century, currently receiving more and more attention. This is because of the increasing market share and promotion of blended cements as alternatives for the traditional Portland cement15–17. These modern cement types are claimed to be more environmentally friendly, thanks to the reduced energy consumption as well as reduced emissions of greenhouse gases such as carbon dioxide during production. Their ability, however, to protect the embedded reinforcing steel from corrosion is still under debate. For holistic assessments of the sustainability of these modern materials, the long-term corrosion performance is crucial. Considering the time to corrosion initiation alone will not permit realistic assessments, because some of the modern binders are known to carbonate substantially faster than Portland cement18–20; thus, it is important to also consider the corrosion propagation stage, which requires the knowledge and prediction of corrosion rates. Finally, the continuously increasing diversity in physical and chemical properties of modern cement types imposes an urgent need for a mechanistic model for the prediction of corrosion rates in carbonated concrete21.
Here, we propose a new mechanism to explain the corrosion rate in carbonated cement-based materials, as a model for dense porous media with a near neutral pore solution (pH ≈ 8–9). Our mechanism combines the capillary condensation theory with corrosion science and electrochemistry. We designed a novel experimental setup22,23 that permits studying the relevant electrical and electrochemical parameters and that allows for fast equilibration with exposure conditions, that is, carbon dioxide and relative humidity (RH) (Fig. 1A) (Supplementary Figures 1 and 2). The main advantage of this is that it permits studying the corrosion process under well-defined conditions, which is not possible in traditional setups that typically include gradients in moisture, carbonation state, and other relevant properties. Various samples were prepared, including two different cement types and three different water/binder (w/b) ratios. After pre carbonation, the corrosion process was studied at different RH by means of a number of electrochemical measurements (Fig. 1B).
Results
Corrosion rate depends mainly on relative humidity
The corrosion rate of steel in carbonated mortar increased dramatically with increasing RH (Fig. 1C and Supplementary Table 1). Changing RH from 50% to 99% raised the corrosion rate by up to two orders of magnitude (Supplementary Figure 3). Compared to this, the water/binder ratio and the cement type were found to be minor influencing factors. These affected the corrosion rate generally by a factor of up to 2–3 (Supplementary Figure 3). Similarly, the cathodic limiting current density (ilim) increased strongly with RH, and was moderately affected by water/binder ratio and cement type (Fig. 1C, Supplementary Table 1 and Supplementary Figure 3). Finally, the impact of these influencing factors was also comparable for the electrical resistivity of the mortar (Fig. 1D, Supplementary Table 1 and Supplementary Figure 3).
There exists a relationship between the corrosion rate and the electrical resistivity of the mortar as shown in Fig. 2A. This is a common form of representing the data24–30, which may ultimately be traced to the widespread hypothesis of a causality between these two parameters. Several authors24–29 suggested that the ohmic resistance of the mortar is the rate-limiting step in the corrosion process, that is, the ion transport between anodic and cathodic sites (through the pore system of the mortar) limiting the corrosion current. However, this mechanistic explanation has been criticized on an experimental basis, pointing out that ohmic control is in contrast with the correlation found between corrosion rate and corrosion potential30,31. Additionally, ohmic control is also unlikely from a theoretical viewpoint, because the uniform type of corrosion, typically observed in carbonated concrete, means that both the anodic and cathodic reactions occur homogeneously and time-variably distributed over the steel surface, forming micro-cells with negligibly small ohmic resistance due to the microscopic distance between the neighboring reaction sites32–34.
The role of the cathodic reaction and the oxygen paradox
Figure 1C and Supplementary Figure 4 show that the cathodic limiting current density was always one order of magnitude higher than the corrosion rate, regardless of the experimental parameters studied. The measured ilim indicate the maximum achievable cathodic reaction current density, which is dictated by the availability of oxygen at the steel surface. These results illustrate that the availability of oxygen at the steel surface was here never a limiting factor for the corrosion rate.
Figure 2B shows the dependency of ilim on RH. Interestingly, ilim increases significantly with increasing RH, that is, the limiting current density increases over approximately 2 orders of magnitude when changing RH from 50% to 99%. This contradicts literature stating that oxygen diffusion is hindered by higher pore water saturation states (higher RH) as a consequence of the difficulties of oxygen to diffuse through water filled pores with respect to empty pores35–40. Figure 2B shows an example of estimated maximum oxygen reduction rates based on oxygen diffusion calculations as a function of RH37. It can be noted that this trend is opposite the present experimental observation. We suggest that this apparent contradiction can be explained largely by the area fraction of the steel surface that is in contact with electrolyte. This will be addressed in more detail in the discussion.
Nevertheless support for this hypothesis can also be found in the observation that icorr and ilim reacted consistently on changes in environmental conditions and depended also in a similar manner on sample-specific conditions (Supplementary Figure 4). This is also apparent from the correlation of the two parameters shown in Fig. 2C.
Discussion
Mixed anodic and cathodic control
The corrosion process is controlled by the kinetics of both the anodic and cathodic partial reactions. This may be represented with the well-known Evans diagram7,41, an example of which is shown in Supplementary Figure 5. As explained earlier, a resistive (ohmic) limitation of icorr can be neglected (due to the uniformity of the corrosion process) and the cathodic reaction is, in the potential range relevant here, not limited by the transport of oxygen (Fig. 1C). Thus, the anodic and cathodic reaction kinetics are essentially defined by their reversible potentials (Ea,rev and Ec,rev), their exchange current densities (ia,o and ic,o), and their Tafel slopes (βa and βc)42. These parameters depend essentially on the chemistry of the electrolyte and on the metal. Variations in these parameters may, in principle, affect the corrosion rate. However, as will be shown below, it is highly unlikely that in the present case, the marked variations in corrosion rate displayed in Fig. 1C were caused by changes in these electrochemical parameters.
In this study, the main influencing variable for icorr was the relative humidity (Fig. 1, Supplementary Figure 3). The relative humidity mainly affects the water content in the mortar pore system. While this influences the amount of water present at the steel surface, it has a secondary influence on the chemical composition of the pore solution. This is because of the extremely high solid/liquid ratio, which keeps the concentrations of most species in the electrolyte close to or at saturation. Thus, concentrations of oxygen and ferrous ions as well as pH are expected to be negligibly affected by RH. Nevertheless, even if minor concentration changes were possible, they can impossibly explain the factor of 200 measured between corrosion rates at 99% and 50% RH. This is because it would mean a concentration difference of ferrous ions of 18 orders of magnitude, a pH difference of 9 units, or an oxygen concentration difference of 35 orders of magnitude (Supplementary Note 1).
Thus, for a given sample (given binder type, w/b ratio, and type of steel), the reversible potentials, the exchange current densities, and the Tafel slopes of the anodic and cathodic partial reactions are expected to be similar for all RH. Consequently, the corrosion current density should also be similar for all RH, here denoted (Supplementary Figure 5). Ge et al. determined the effect that variation of exchange current densities, reversible potentials and Tafel slopes would have on the corrosion rate based on the data found in literature43. They showed that these parameters, as per the scatter found in the literature, can lead to a corrosion rate variation of a maximum factor of 3.
In summary, the high variations of observed corrosion rate when changing RH (Fig. 1C) can neither be explained by the electrochemistry of the corroding system, nor by kinetic limitations arising from the ohmic resistivity of the pore system, nor by limited oxygen availability. Our hypothesis is that a simple area effect, arising from RH-depending steel surface wetting in the concrete pore system, can explain these variations in observed corrosion rate.
The electrochemically active area controls the corrosion current
The moisture state of concrete has an influence on the portion of the steel area that is in contact with liquid water. At low RH, large pores and voids may be air-filled with only a few monolayers of adsorbed water present on the steel surface44. In these thin films of water, electrochemical reactions are strongly limited, among other reasons because any transport of charged species involved in the anodic and cathodic processes is hardly possible45–47. Capillary pores, on the other hand, may according to the capillary condensation theory48 be stably filled with liquid water. In pores filled with solution, electrochemical reactions will be enabled to occur in a similar manner as in a bulk solution.
The condensation of water in porous systems can be described by the Kelvin-Laplace equation49–51. This equation describes both the stable meniscus, r, and the pressure in the liquid phase, pl, as a function of RH:
1 |
2 |
Here, r can be considered the maximum stably water-filled pore radius, is the surface tension of water-air, is the molar volume of water, R is the ideal gas constant, and T is the temperature. Figure 3A illustrates the strongly nonlinear nature of these relationships. Cementitious materials are characterized by a wide pore size distribution (from approx. 1 nm up to the micrometer scale), which means that as the relative humidity varies, a different volumetric fraction of this porosity is water-filled. At low to intermediate RH, the pore liquid may in small pores at the steel-concrete interface be under considerable tension and not be able to behave as a liquid52–54. Only at high RH (>80%) is the tension reduced to a level approaching bulk solution behavior. At the same time, the radius of stably water-filled pores increases strongly nonlinearly with increasing RH. As a consequence of these two facts, the area of steel surface being in contact with liquid water capable of behaving as an electrolyte, Aactive, can be expected to increase also nonlinearly with RH. The result is a nonlinear increase of the water filled porosity, which determines an increase of the steel surface area being in contact with liquid water (Fig. 4).We suggest the following proportional relationship between area fraction and RH:
3 |
Here, Anominal is the surface area of the steel in contact with pores and voids in the concrete (not shielded by adherent solid phases), and Aactive is the fraction of this area at which electrochemical processes can occur (Fig. 3B). We acknowledge that the transition from electrochemically “inactive” areas to “active” areas is gradual (Fig. 3A). Nevertheless, the concept of introducing an area fraction according to eq. (3) is considered a valid approach to take into account the fact that a significant portion of the steel surface is, below saturation, not in conditions that permit the occurrence of electrochemical reactions (because it is either only wetted with a few monolayers of adsorbed water or because the water held in gel pores is under considerable tension).
Figure 3C provides evidence for this suggested approach (eq. 3), as the concept of an electrochemically active area fraction can very well explain the large experimentally observed variations (Fig. 1C) in measured corrosion current density icorr. The red curve in Fig. 3C can be expressed as follows:
4 |
Here, icorr,app means the apparent corrosion rate, that is, the corrosion rate that is experimentally obtained when a measured corrosion current is divided by the total embedded steel surface area Asteel. We suggest that icorr,app can be calculated as the product of the maximum corrosion current density, hypothetically achievable at full saturation of all pores, and the area ratio . The maximum achievable corrosion current density is.
5 |
Here, indicates the corrosion current density determined by the anodic and cathodic reaction kinetics. As discussed above, these are largely independent of RH, thus is here assumed a constant. An exception to this may be the influence of the ferrous ion concentration at the steel surface affecting the electrode kinetics, or prolonged (as opposed to short-term) saturation, leading to limited oxygen availability. This will be addressed in more detail below.
Figure 3B also shows a qualitative correspondence with ilim as well as with the inverse of the electrical resistivity. This can be explained by the fact that these two parameters are directly related to the electrochemically active steel surface area.
Implication for corrosion of metals in porous media
We believe that the here exposed theory presents a major step ahead in the understanding of electrical and electrochemical processes in unsaturated porous media, particularly of dense porosity, that is, pore sizes where capillary condensation is possible. While it is well known that water – in conditions able to behave as an electrolyte, thus permitting transport of ions – is essential for electrical and electrochemical processes to occur, the related effects of the degree of pore saturation and tension in the capillary water, are typically not considered in studies addressing corrosion rates in porous media.
Models for the prediction of corrosion rates of steel in carbonated concrete are mainly based on the assumption that oxygen reduction is the rate-limiting step of the process37,40,55, or on a calculation of corrosion rate from oxygen concentration and resistivity56. As shown in this article, the parameters that are at the base of these models can, however, not explain the behavior and magnitude of the corrosion process in unsaturated porous media, where the cathodic limiting current density appears to be always 10 times higher than the corrosion rate – even at high RH such as 99%. We do not generally exclude that oxygen diffusion through the concrete cover may become a rate limiting step. However, for this to occur, extremely long and permanently fully saturated conditions are needed until all dissolved and gaseous oxygen (present in air voids within the concrete), becomes consumed and further supply is possible only from the exterior of the concrete. In typical carbonation exposure conditions, the moisture state of the pore system of concrete is below saturation. This is because carbonation is fastest around average RHs of 60–70%7. Under conditions of prolonged wetting (e.g. submerged conditions), carbonation typically occurs at negligibly low rates57 and does hardly reach the steel depth within the service life of a structure. Thus, in exposure conditions that favor carbonation, such as constantly relatively dry conditions (60–70% RH) or cyclic wetting/drying exposure, a substantial portion of the pores in the concrete is always filled with air, and thus oxygen. As a consequence, we consider the limitation of oxygen availability at the steel surface by transport, that is diffusion exclusively through the liquid phase of the pore system (as predicted in Fig. 2, blue line), hardly relevant for corrosion in carbonated concrete in the vast majority of practical situations.
In addition to models for the corrosion rate, the here suggested approach might greatly influence the conception of corrosion-induced concrete cracking. Acknowledging that it is the steel area fraction on which corrosion processes occur, which changes dramatically upon RH changes, rather than the actual corrosion current density (the corrosion rate per unit wet and electrochemically active area, ), has dramatic consequences for the distribution of corrosion products and the consequent localization of stresses due to the crystallization in the porous system. Concrete cracking due to precipitation of corrosion products cannot be simulated by models based on uniform corrosion assuming release of corrosion products into the concrete pore system homogeneously distributed over the entire steel surface.
The main strength of our theory can be found in its simplicity. Predictions of corrosion kinetics in dense porous media rely on just two conceptual aspects: i) the inverse proportionality between the electrochemically active steel surface ratio () and the logarithm of the relative humidity (eq. 3), grounded on the theory of capillary condensation, and ii) the corrosion current density that, according to corrosion science, establishes depending on metal surface properties and electrolyte chemistry – however largely independent of RH. Further work should aim at quantifying the proportionality constant needed for eq. (3), on the basis of material properties, such as porosity and pore size distribution, while electrochemistry and sound corrosion science can deliver . To take into account that the microstructure of the concrete at the steel-concrete interface may differ from regions further away58, further work should also characterize the porosity and pore size distribution of the volume that directly controls the water distribution and the electrolyte chemistry at the steel surface.
Concluding remarks
The experimental results presented in this work show that the by far most dominant factor influencing the corrosion rate in carbonated concrete is the moisture state. A fundamentally new approach – combining the capillary condensation theory with electrochemistry – was proposed to explain the scientific mechanism of corrosion kinetics in dense porous media. It was shown that capillary condensation in the pore structure defines the electrochemically active steel surface, the variation of which explains the orders of magnitude over which the measured corrosion rates span.
The proposed conceptual model lays the basis for reliable predictions of corrosion rates in various dense porous media in a multitude of exposure conditions. For the case of reinforcing steel corrosion in carbonated concrete, to guarantee safety, serviceability, and sustainability of engineering structures, enhancing the predictions of the performance in actual exposure conditions is more urgently needed than ever, mainly due to the continuing loss of alkalinity in modern and future cement types that was discussed in the introduction.
Materials and Methods
Test sample specifications
The samples (dimension 80 × 80 × 6 mm3, Fig. 1A) were cast with embedded carbon steel (St 37) wires (diameter = 0.5 mm) serving as working electrodes, a stainless steel grid (10 × 100 × 1 mm3), to be used as counter electrode, and an embedded Ag/AgCl sensor acting as reference electrode for the electrochemical tests22,23 (Supplementary Figures 1 and 2). In total, 4 samples per kind were prepared, each of them allowed for 2 different measurements of corrosion rate and resistivity and 1 measurement of cathodic limiting current. That means the averages and standard deviations are made out of 8 measurements for corrosion rate and matrix resistivity and 4 measurements for the cathodic limiting current.
Mix design
In order to evaluate the influence of different pore structures, 6 different types of specimens were tested. These were produced by varying the binder type and the water to binder ratio (w/b); two different cements and three different w/b ratios were used: the binders CEM I 52,5 R and CEM II/B-M (T-LL) 42,5; the w/b ratios were 0.4, 0.5 and 0.6.
The mix design was chosen to allow the best fluidity while maintaining a high stability of the cementitious suspension. The sand/binder ratio was 2 and the sand had a maximum particle diameter of 1 mm. A poly-carboxylate ether superplasticizer with de-foaming agent was added to the mixes with w/c 0.4 and 0.5 (0.6% and 0.2% by weight of binder, respectively) in order to increase the fluidity and thus permitting filling the mould; the amount was chosen in order to achieve a visually similar fluidity of the mortars. The specimens were demoulded after one day and cured at 95% RH for 7 days before being carbonated.
Carbonation procedure
The samples were carbonated in a carbonation chamber at 20 °C, 57% relative humidity and 4% CO2 concentration. The time required for complete carbonation was:
3 to 7 days for CEM II mortars;
7 to 14 days for CEM I mortars.
These durations were obtained by the phenolphthalein test on companion samples, prior to this experimental study. The phenolphthalein indicator allows for a rough evaluation of the pH value and it is widely used in carbonation studies in the field of cementitious materials;59 in a non-carbonated sample the indicator gives a bright purple color, which indicates the pH is higher than 9.9. In the interval 8.0–9.9 the coloring shades away, until it disappears below pH 8. In this study the carbonation process is not under evaluation, but complete carbonation of the material is needed in order to trigger the corrosion process. To ensure complete carbonation of the samples used for the present study, a safety extra-time in the carbonation chamber was applied: CEM II mortars were carbonated for 2 weeks and CEM I mortars for 3 weeks.
Exposure conditions
After carbonation, the samples were studied in different exposure conditions of controlled and constant environments (Fig. 1B): 50% RH, 81% RH, 95% RH and 99% RH; at a constant temperature of 20 °C. The relative humidity was controlled by means of either climatic conditioning rooms (50% RH and 95% RH) or of saturated Ammonium Sulfate solution (81% RH) or ultrapure water (99% RH), taking care no water condensation would take place in the container by keeping the temperature constant.
Time to equilibration
Monitoring of the mass of the samples showed a weight equilibration for all the different samples, at a constant relative humidity, after 1 to 2 weeks. The measurements of all the parameters started after minimum 2 months of exposure at a constant relative humidity, once stable conditions were achieved (Fig. 1B).
Electrochemical tests
All the electrochemical tests were performed using a potentiostat Metrohm Autolab PGSTAT30. The embedded Ag/AgCl sensor was always used as reference electrode and its reference potential was checked by means of an external Ag/AgCl reference electrode. One carbon steel wire was used as working electrode and the stainless steel grid was used as counter electrode. The measurements were repeated over time for each exposure condition. The electrolyte of the electrochemical system is the aqueous phase condensed in the pore structure in equilibrium with environmental humidity.
Corrosion rate: the instantaneous corrosion current density was determined by polarization resistance measurements. The polarization resistance Rp′ of the single steel wires was measured at ± 10 mV around the open circuit potential with a scan rate of 0.1 mV/s. The IR-drop in the mortar was taken into account indirectly. Impedance measurements (see below) were performed right before each polarization resistance test, and the obtained ohmic resistance RΩ was subtracted from the total resistance Rp′ to get the IR drop-free polarization resistance values Rp.
The corrosion rate, icorr, was then calculated using the following equation:
6 |
Where B is a parameter depending on the electrochemical properties of the considered system; for iron in actively corroding state a value of 26 mV is commonly used.
Ohmic resistance RΩ: in the same electrode configuration as for the polarization resistance tests, the electrical resistance was measured by means of electrochemical impedance spectroscopy (50 frequencies logarithmically distributed between 105 and 1 Hz, voltage amplitude = 10 mV). The value of ohmic resistance RΩ was extrapolated by fitting of the first semicircle appearing in the Nyquist plot and considering the value first intercepted on the real impedance axis.
Electrical resistivity: the resistivity of the mortars was calculated by converting RΩ to resistivity with a cell constant (0.05 cm) that was determined experimentally, that is, by measuring the ohmic resistance between two disk electrodes placed on the facing sides of the mortar samples.
Cathodic limiting current density: cathodic potentiostatic polarization tests were carried out by imposing a potential 500 mV cathodic to the open circuit potential. The resulting current decay was monitored for 30 minutes, at the end of which the steady state current was recorded. For this test, a different steel wire of the sample was used, that was not used for corrosion rate measurements in order not to compromise the surface state. In this case the IR-drop compensation was directly applied as an input to the polarization procedure, the value was set as 80% of the extrapolated ohmic resistance from impedance measurement carried out using the electrode configuration as for the cathodic polarization.
Data availability
The experimental data supporting the findings of this study and used to create the figures are available in the paper’s Supplementary Information. All the other data are available from the corresponding author(s) upon request.
Electronic supplementary material
Acknowledgements
Research supported by the Swiss National Foundation for Research (SNF) project no. 154062 entitled “Formulation, use and durability of concrete with low clinker cements” is gratefully acknowledged.
Author Contributions
M.S. was the main investigator. He planned and carried out the experiments. M.S., U.A. and B.E. contributed to the analysis and interpretation of the results and to the preparation of the manuscript.
Competing Interests
The authors declare no competing interests.
Footnotes
Electronic supplementary material
Supplementary information accompanies this paper at 10.1038/s41598-018-25794-x.
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Gupta SK, Gupta BK. The critical soil moisture content in the underground corrosion of mild steel. Corros. Sci. 1979;19(3):171–178. doi: 10.1016/0010-938X(79)90015-5. [DOI] [Google Scholar]
- 2.Rawat NS. Corrosivity of underground mine atmospheres and mine waters: A review and preliminary study. Br. Corros. J. 1976;11(2):86–91. doi: 10.1179/000705976798320179. [DOI] [Google Scholar]
- 3.Gardiner CP, Melchers RE. Corrosion of mild steel in porous media. Corros. Sci. 2002;44(11):2459–2478. doi: 10.1016/S0010-938X(02)00062-8. [DOI] [Google Scholar]
- 4.Zelinka, S. L. Corrosion of metals in wood products in Developments in Corrosion Protection (InTech, 2014).
- 5.Kear G, Wú HZ, Jones MS. Weight loss studies of fastener materials corrosion in contact with timbers treated with copper azole and alkaline copper quaternary compounds. Corros. Sci. 2009;51(2):252–262. doi: 10.1016/j.corsci.2008.11.012. [DOI] [Google Scholar]
- 6.Mehta, P. K. & Monteiro, P. J. M. Concrete: Microstructure, Properties, and Materials (McGraw-Hill Publishing, 2013).
- 7.Bertolini, L., Elsener, B., Pedeferri, P., Redaelli, E. & Polder, R. B. Corrosion of Steel in Concrete: Prevention, Diagnosis, Repair (John Wiley & Sons, 2013).
- 8.Jones AEK, et al. Development of an holistic approach to ensure the durability of new concrete construction. British Cement Association. Report for the Department of Environment. 1997;78:0–7210. [Google Scholar]
- 9.Angst UM. Challenges and opportunities in corrosion of steel in concrete. Mater. Struct. 2018;51(1):4. doi: 10.1617/s11527-017-1131-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Winslow DN, Cohen MD, Bentz DP, Snyder KA, Garboczi EJ. Percolation and pore structure in mortars and concrete. Cem. Concr. Res. 1994;24(1):25–37. doi: 10.1016/0008-8846(94)90079-5. [DOI] [Google Scholar]
- 11.Vollpracht A, Lothenbach B, Snellings R, Haufe J. The pore solution of blended cements: a review. Mater. Struct. 2016;49(8):3341–3367. doi: 10.1617/s11527-015-0724-1. [DOI] [Google Scholar]
- 12.Chang, C. F. & Chen, J. W. The experimental investigation of concrete carbonation depth. 36(9), 1760–1767 (2006).
- 13.Parrot, L. A review of carbonation in reinforced concrete. British Cement Association. BRE/BCA Report C/1 (1987).
- 14.Stefanoni M, Angst U, Elsener B. Corrosion rate of carbon steel in carbonated concrete–A critical review. Cem. Concr. Res. 2018;103:35–48. doi: 10.1016/j.cemconres.2017.10.007. [DOI] [Google Scholar]
- 15.Olivier, J. G., Peters, J. A. & Janssens-Maenhout, G. Trends in global CO2 emissions; 2012 report, PBL Netherlands Environmental Assessment Agency (2012).
- 16.Oggioni G, Riccardi R, Toninelli R. Eco-efficiency of the world cement industry: a data envelopment analysis. Energ. Policy. 2011;39(5):2842–2854. doi: 10.1016/j.enpol.2011.02.057. [DOI] [Google Scholar]
- 17.Schneider M, Romer M, Tschudin M, Bolio H. Sustainable cement production—present and future. Cem. Concr. Res. 2011;41(7):642–650. doi: 10.1016/j.cemconres.2011.03.019. [DOI] [Google Scholar]
- 18.Leemann A, Nygaard P, Kaufmann J, Loser R. Relation between carbonation resistance, mix design and exposure of mortar and concrete. Cem. Concr. Compos. 2015;62:33–43. doi: 10.1016/j.cemconcomp.2015.04.020. [DOI] [Google Scholar]
- 19.Younsi A, Turcry P, Aït-Mokhtar A, Staquet S. Accelerated carbonation of concrete with high content of mineral additions: effect of interactions between hydration and drying. Cem. Concr. Res. 2013;43:25–33. doi: 10.1016/j.cemconres.2012.10.008. [DOI] [Google Scholar]
- 20.Papadakis VG. Effect of supplementary cementing materials on concrete resistance against carbonation and chloride ingress. Cem. Concr. Res. 2000;30(2):291–299. doi: 10.1016/S0008-8846(99)00249-5. [DOI] [Google Scholar]
- 21.Angst UM, et al. Present and future durability challenges for reinforced concrete structures. Mater. Corros. 2012;63(12):1047–1051. doi: 10.1002/maco.201206898. [DOI] [Google Scholar]
- 22.Stefanoni, M., Angst, U. & Elsener, B. Innovative sample design for corrosion rate measurement in carbonated concrete. 11th annual International Concrete Sustainability Conference. Washington DC, USA (2016).
- 23.Stefanoni, M., Angst, U. & Elsener, B. A New Setup for Rapid Durability Screening of New Blended Cements. 2ndConcrete Innovation Conference. Trosmo, Norway (2017).
- 24.Alonso C, Andrade C. Effect of cement type and cement proportion in the corrosion rate of rebars embedded in carbonated mortar. Mater. Construcc. 1987;37(205):5–15. doi: 10.3989/mc.1987.v37.i205.874. [DOI] [Google Scholar]
- 25.Alonso C, Andrade C, González JA. Approach to the effect of concrete resistivity in the corrosion of rebars in concrete. Mater. Construcc. 1987;37(207):5–12. doi: 10.3989/mc.1987.v37.i207.859. [DOI] [Google Scholar]
- 26.Alonso C, Andrade C, Gonzalez JA. Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types. Cem. Concr. Res. 1988;18(5):687–698. doi: 10.1016/0008-8846(88)90091-9. [DOI] [Google Scholar]
- 27.Sergi, G., Lattey, S. E. & Page, C. L. Influence of surface treatments on corrosion rates of steel in carbonated concrete. Corrosion of Reinforcement in Concrete, 409–419 (1990).
- 28.Smith KM, Schokker AJ, Tikalsky PJ. Performance of supplementary cementitious materials in concrete resistivity and corrosion monitoring evaluations. ACI Mater. J. 2004;101(5):385–390. [Google Scholar]
- 29.Chávez-Ulloa E, Camacho-Chab R, Sosa-Baz M, Castro-Borges P, Pérez-López T. Corrosion process of reinforced concrete by carbonation in a natural environment and an accelerated test chamber. Int. J. Electrochem. Sci. 2013;8(7):9015–9029. [Google Scholar]
- 30.Glass GK, Page CL, Short NR. Factors affecting the corrosion rate of steel in carbonated mortars. Corros. Sci. 1991;32(12):1283–1294. doi: 10.1016/0010-938X(91)90048-T. [DOI] [Google Scholar]
- 31.Feliu S, Gonzalez JA, Feliu S, Andrade C. Relationship between conductivity of concrete and corrosion of reinforcing bars. Br. Corros. J. 1989;24(3):195–198. doi: 10.1179/000705989798270027. [DOI] [Google Scholar]
- 32.Ji YS, Zhan G, Tan Z, Hu Y, Gao F. Process control of reinforcement corrosion in concrete. Part 1: Effect of corrosion products. Constr. Build. Mater. 2015;79:214–222. doi: 10.1016/j.conbuildmat.2014.12.083. [DOI] [Google Scholar]
- 33.Gulikers J. Theoretical considerations on the supposed linear relationship between concrete resistivity and corrosion rate of steel reinforcement. Mater. Corros. 2005;56(6):393–403. doi: 10.1002/maco.200403841. [DOI] [Google Scholar]
- 34.Hornbostel K, Larsen CK, Geiker MR. Relationship between concrete resistivity and corrosion rate–A literature review. Cem. Concr. Compos. 2013;39:60–72. doi: 10.1016/j.cemconcomp.2013.03.019. [DOI] [Google Scholar]
- 35.Lopez W, Gonzalez JA. Influence of the degree of pore saturation on the resistivity of concrete and the corrosion rate of steel reinforcement. Cem. Concr. Res. 1993;23(2):368–376. doi: 10.1016/0008-8846(93)90102-F. [DOI] [Google Scholar]
- 36.Houst YF, Wittmann FH. Influence of porosity and water content on the diffusivity of CO2 and O2 through hydrated cement paste. Cem. Concr. Res. 1994;24(6):1165–1176. doi: 10.1016/0008-8846(94)90040-X. [DOI] [Google Scholar]
- 37.Huet B, L’hostis V, Santarini G, Feron D, Idrissi H. Steel corrosion in concrete: Determinist modeling of cathodic reaction as a function of water saturation degree. Corros. Sci. 2007;49(4):1918–1932. doi: 10.1016/j.corsci.2006.10.005. [DOI] [Google Scholar]
- 38.Hunkeler, F. Monitoring of repaired reinforced concrete structures by means of resistivity measurements in Materials Science Forum247, 93-106. (Trans Tech Publications, 1997).
- 39.Hunkeler F. The resistivity of pore water solution—a decisive parameter of rebar corrosion and repair methods. Constr. Build. Mater. 1996;10(5):381–389. doi: 10.1016/0950-0618(95)00029-1. [DOI] [Google Scholar]
- 40.Nguyen TTH, Bary B, De Larrard T. Coupled carbonation-rust formation-damage modeling and simulation of steel corrosion in 3D mesoscale reinforced concrete. Cem. Concr. Res. 2015;74:95–107. doi: 10.1016/j.cemconres.2015.04.008. [DOI] [Google Scholar]
- 41.McCafferty, E. Introduction to Corrosion Science. (Springer Science & Business Media, 2010).
- 42.Wagner C, Traud W. On the Interpretation of Corrosion Processes through the Superposition of Electrochemical Partial Processes and on the Potential of Mixed Electrodes, with a Perspective by F. Mansfeld. Corrosion. 2006;62(10):843–855. doi: 10.5006/1.3279894. [DOI] [Google Scholar]
- 43.Ge J, Isgor OB. Effects of Tafel slope, exchange current density and electrode potential on the corrosion of steel in concrete. Mater. Corros. 2007;58(8):573–582. doi: 10.1002/maco.200604043. [DOI] [Google Scholar]
- 44.Leygraf, C., Wallinder, I. O., Tidblad, J. & Graedel, T. Atmospheric Corrosion (John Wiley & Sons, 2016).
- 45.Asay DB, Kim SH. Evolution of the adsorbed water layer structure on silicon oxide at room temperature. J. Phys. Chem. B. 2005;109(35):16760–16763. doi: 10.1021/jp053042o. [DOI] [PubMed] [Google Scholar]
- 46.Revil A. Ionic diffusivity, electrical conductivity, membrane and thermoelectric potentials in colloids and granular porous media: a unified model. J. Colloid Interface Sci. 1999;212(2):503–522. doi: 10.1006/jcis.1998.6077. [DOI] [PubMed] [Google Scholar]
- 47.Revil A, Glover PWJ. Theory of ionic-surface electrical conduction in porous media. Phys. Rev. B: Condens. Matter. 1997;55(3):1757. doi: 10.1103/PhysRevB.55.1757. [DOI] [Google Scholar]
- 48.Brunauer S, Deming LS, Deming WE, Teller E. On a theory of the van der Waals adsorption of gases. Journal of the American Chemical society. 1940;62(7):1723–1732. doi: 10.1021/ja01864a025. [DOI] [Google Scholar]
- 49.Lura P, Jensen OM, Van Breugel K. Autogenous shrinkage in high-performance cement paste: An evaluation of basic mechanisms. Cem. Concr. Res. 2003;33(2):223–232. doi: 10.1016/S0008-8846(02)00890-6. [DOI] [Google Scholar]
- 50.Johannesson B, Utgenannt P. Microstructural changes caused by carbonation of cement mortar. Cem. Concr. Res. 2001;31(6):925–931. doi: 10.1016/S0008-8846(01)00498-7. [DOI] [Google Scholar]
- 51.Hunter, R. J. Foundations of Colloid Science (Oxford University Press, 2001).
- 52.Ball P. Chemical physics: how to keep dry in water. Nature. 2003;423(6935):25–26. doi: 10.1038/423025a. [DOI] [PubMed] [Google Scholar]
- 53.Dokter AM, Woutersen S, Bakker HJ. Inhomogeneous dynamics in confined water nanodroplets. Proc. Natl. Acad. Sci. USA. 2006;103(42):15355–15358. doi: 10.1073/pnas.0603239103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Mashl RJ, Joseph S, Aluru NR, Jakobsson E. Anomalously immobilized water: a new water phase induced by confinement in nanotubes. Nano Lett. 2003;3(5):589–592. doi: 10.1021/nl0340226. [DOI] [Google Scholar]
- 55.Hussain RR, Ishida T. Development of numerical model for FEM computation of oxygen transport through porous media coupled with micro-cell corrosion model of steel in concrete structures. Comp. Struct. 2010;88(9):639–647. doi: 10.1016/j.compstruc.2010.02.008. [DOI] [Google Scholar]
- 56.Ghods P, Isgor OB, Pour-Ghaz M. Experimental verification and application of a practical corrosion model for uniformly depassivated steel in concrete. Mater. Struct. 2008;41(7):1211–1223. doi: 10.1617/s11527-007-9320-3. [DOI] [Google Scholar]
- 57.Steffens A, Dinkler D, Ahrens H. Modeling carbonation for corrosion risk prediction of concrete structures. Cem. Concr. Res. 2002;32(6):935–941. doi: 10.1016/S0008-8846(02)00728-7. [DOI] [Google Scholar]
- 58.Angst UM, et al. The steel–concrete interface. Mater. Struct. 2017;50(2):143. doi: 10.1617/s11527-017-1010-1. [DOI] [Google Scholar]
- 59.Chang CF, Chen JW. The experimental investigation of concrete carbonation depth. Cem. Concr. Res. 2006;36(9):1760–1767. doi: 10.1016/j.cemconres.2004.07.025. [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The experimental data supporting the findings of this study and used to create the figures are available in the paper’s Supplementary Information. All the other data are available from the corresponding author(s) upon request.