Skip to main content
. 2018 Mar 19;23(3):175–182. doi: 10.1016/j.rpor.2018.02.007

Table 1.

Dose objectives for all regions of interest.

ROI Objectives
Brain stem D0.1cc = 54 Gy
Spinal cord D0.1cc ≤ 44–45 Gy
Mandible D1cc = 70–73.5 Gy
Larynx Dmean = 44 Gy
D1cc = 73.5 Gy
Thyroid V45 Gy < 50%
Esophagus D1cc = 45 Gy
Parotids Dmean ≤ 26 Gy
V30 Gy < 50%
Salivary glands Dmean ≤ 35 Gy
Ring 1 D2% = 95% prescribed dose to PTV3
Ring 2 D2% = 80% prescribed dose to PTV3
PTVn Dmin = 80% prescribed dose to PTVn
PTVn eval D95% = 95% prescribed dose to PTVn
Dmin = 90% prescribed dose to PTVn
D2% = 105% prescribed dose to PTVn
Uniform dose = prescribed dose to PTVn

Abbreviations: ROI = region of interest; PTV = planning target volume.