Fault diagnosis results for Dataset 1 for the proposed method and ALPIO when torque load = 0 hp.

Algorithms Proposed Method ALPIO
Crack Diameters (in) 0.007 0.014 0.021 0.007 0.014 0.021
Normal State 100% 100% 100% 89% 89% 89%
IR Faults 96% 93% 96% 66% 70% 70%
OR Fault 100% 100% 100% 75% 80% 78%
Ball Fault 100% 100% 100% 81% 81% 84%
Average 99% 98.3% 99% 78% 80% 80.3%